A novel multiplex-protein array for serum diagnostics of colorectal cancer: impact of pre-analytical storage conditions.
Bünger S, Klempt-Giessing K, Toner V, Kelly M, FitzGerald SP, Brenner H, von Eggeling F, Habermann JK
Purpose
The purpose of this paper was to determine the effects of frozen storage temperature and up to 3 freeze-thaw cycles on the levels of 8 proteins in serum from patients with colorectal cancer.
Conclusion
Storing serum at -80 rather than -170 degrees C had no significant effects on levels of the 8 tested proteins, but non-significant decreases in carcinoembryonic antigen (CEA) with storage at -80 degrees C were large enough to lead to a false negative malignancy result for 1 of 3 patients. In contrast, while freeze-thaw cycling had no diagnostic impact, it led to significantly increased levels of CEA, Interleukin-8 (IL-8), complement component 3 a (C3adesArg) and C-reactive protein (CRP) and decreased levels of vascular endothelial growth factor (VEGF). Macrophage colony-stimulating factor (M-CSF) levels were lower after 2 freeze-thaw cycles than 1, but after 3 freeze-thaw cycles, M-CSF levels were comparable to those measured after 1 freeze-thaw cycle. Calgizzarin (S100A1) and CD26 were not affected by freeze-thaw cycling of serum.
Studies (1)
Purpose
The purpose of this study was to determine the effects of frozen storage temperature and up to 3 freeze-thaw cycles on the levels of 8 proteins in serum from patients with colorectal cancer. Serum specimens were collected from 20 patients during post-operative follow-ups. Serum was stored, within 30 min of collection, at both -80 and -170 degrees C. Specimens were stored for 22.2-35.7 months before thawing on ice and analysis. Specimens that had been stored at -170 degrees C were returned to liquid nitrogen, thawed and assayed again 24 and 48 h later. Protein levels were determined using a multiplex chemiluminescent sandwich immunoassay biochip.
Summary of Findings
Nonsignificant decreases in the levels of CD26 and CRP, and nonsignificant increases in IL-8, VEGF, S100A11, and C3adesArg were observed when serum was stored at -80 degrees C rather than at -170 degrees C. The decrease in CEA levels with storage at -80 degrees C was large enough to lead to a false negative malignancy result for 1 of 3 patients. In contrast, while freeze-thaw cycling had no diagnostic impact, it led to significantly increased levels of CEA (p<0.001), IL-8 (p<0.001), C3adesArg (p<0.001) and CRP (p=0.043) and significantly decreased levels of VEGF (p<0.0001). M-CSF levels were lower after 2 freeze-thaw cycles than 1 (p=0.002), but after 3 freeze-thaw cycles, M-CSF levels were comparable to those measured after 1 freeze-thaw cycle. S100A1 and CD26 levels were not affected by freeze-thaw cycling of serum.
Biospecimens
FluidSerumPreservation Types
FrozenDiagnoses
NeoplasticCarcinomaPlatforms
ProteinImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Freeze/thaw cycling 1 cycle2 cycles3 cyclesStorage Storage temperature -170 degrees C-80 degrees C