Comparing the MicroRNA spectrum between serum and plasma.

Wang K, Yuan Y, Cho JH, McClarty S, Baxter D, Galas DJ

Publication: PLoS One (2012) • Vol 7 • Page e41561PMID: 22859996View on PubMed

Purpose

The purpose of this paper was to compare levels of circulating microRNA (miR, miRNA) in blood components, and to examine potential differences associated with the real-time PCR panel manufacturer on the quantification of miRNA in plasma and serum.

Conclusion

RNA yields were highest in red blood cells (RBCs) followed by white blood cells (WBCs), platelets (Plts), serum and then plasma. While 26 miRNA were only found in RBCs, only 1 miRNA (miR-24-5p) was found exclusively in WBCs. Serum and plasma had largely overlapping miRNA profiles, but generally serum had higher levels of individual miRNA than plasma and expressed more miRNA forms. The number of miRNA detected, quantifiable levels and their variability differed between Exiqon and Taqman panels. The average cycle threshold (CT) value was 6.5 cycles lower using Taqman panels than Exiqon panels. miRNA levels measured by Taqman and Exiqon panels were only weakly correlated. Importantly, U6, small nucleolar RNA 44 (RNU44, SNORD 44) and RNU48 (SNORD48), which often serve as miRNA controls, were not detected in every plasma, serum, Plt, RBC or WBC specimens and when they were expressed the authors report high variability among specimens. The authors report no association between patient age or gender and RNA concentration, or number of detectable miRNA using either platform, but report gender-specific expression patterns for some miRNA.

Studies (1)

Purpose

The purpose of this study was to compare levels of circulating miRNA in blood components and to examine potential differences associated with the real-time PCR panel manufacturer on levels of miRNA in plasma and serum. Matched serum and EDTA plasma were obtained from 12 healthy patients and for 6 of these patients RBCs, Plts and WBCs were also obtained. miRNA was extracted using the miRNeasy kit. miRNA levels were quantified in 10 paired serum and plasma specimens, and 6 matched RBC, WBC and Plts specimens using Exiqon panels and in 6 paired serum and plasma specimens using Taqman panels. Only 4 plasma and serum specimens were quantified by both platforms.

Summary of Findings

RNA concentrations were highest in RBCs followed by WBCs, Plts, serum and then plasma. Interestingly, the electropherogram of the RNA was similar among Plts, plasma and serum, but distinct from that of RBCs and WBCs. Of the 742 miRNA assayed, 178 were nondetectable in any of the specimens, 206 were detected in blood cell components (RBC, WBC and Plt) and 80 were detected in all specimen types (RBC, WBC, Plt, plasma and serum). While 26 miRNA were only found in RBCs, only 1 miRNA (miR-24-5p) was found exclusively in WBCs. Serum generally had higher levels of individual miRNA than plasma and expressed more miRNA types, but the difference in levels was only significant when assayed using Exiqon panels (p=0.0379). Of the 742 miRNA assayed using Exiqon panels, 90 and 99 miRNAs were detected in all 6 plasma and serum specimens, respectively, and 83 were detected in every plasma and every serum specimen. The greatest variability in miRNA levels was observed in  miR-22 in plasma and miR-29c in serum, while miR-92a and miR-720 were the least variable in plasma and serum, respectively. Of the 384 miRNA assayed by TaqMan panels, 106 and 118 miRNA were detected in all 6 plasma and serum specimens, respectively, and 98 were detected in every plasma and every serum specimen. The greatest variability in miRNA levels quantified with TaqMan panels was observed with miR-101 and miR-576-3p in plasma and serum, respectively, while miR-185 miR-345 were the least variable in plasma and serum, respectively. While 358 miRNA were assayed using both real-time qPCR panel types, only 67 miRNA were detected in all plasma and serum specimens using both platforms. The average CT value was 6.7 cycles lower using Taqman than Exiqon panels, although the opposite was true for several miRNAs. miRNA levels measured by Taqman were weakly correlated with those measured by Exiqon (R2=0.3136 for serum and R2=0.3236 for plasma). Importantly, U6, RNU44 (SNORD 44) and RNU48 (SNORD48), which often serve as controls, were not detected in all plasma, serum, Plt, RBC or WBC specimens and when expressed were highly variable. The authors report no association between patient age or gender and RNA concentration, or number of detectable miRNA using either platform. However, the authors report gender-dependent expression of some miRNA, and cited higher levels of miR-130b and miR-18b in serum from males compared to females as an example.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
    CellRed Blood Cells
    CellWhite Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    RNALow density array
    RNAReal-time qRT-PCR
    RNAAutomated electrophoresis/Bioanalyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    22-41 years
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen Aliquots and ComponentsBlood and blood products
    Leukocyte
    Plasma
    Platelets
    Red blood cells
    Serum
    Low density array SpecificTargeted nucleic acid
    RNU44
    RNU48 (SNORD48)
    U6
    miR-101
    miR-130b
    miR-185
    miR-18b
    miR-22
    miR-24-5p
    miR-29c
    miR-345
    miR-576-3p
    miR-720
    miR-92a
    Low density array SpecificType of array
    Exiqon low density arrays
    TaqMan low density arrays