Processing of diagnostic blood specimens: is it really necessary to mix primary blood tubes after collection with evacuated tube system?
Lima-Oliveira G, Lippi G, Salvagno GL, Brocco G, Gaino S, Dima F, Volaski W, Rego FG, Picheth G, Guidi GC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of delaying or eliminating the mixing step during blood collection on clinical chemistry, hematology, and coagulation parameters. Specimens were collected from 300 outpatient volunteers in either sodium citrate, lithium heparin, or K2EDTA vacuum tubes. Hematological parameters were evaluated within 15 min of blood collection. Centrifugation protocols were different between the tube types, and the authors do not examine the effects of the different anticoagulants, but once plasma was separated, it was stored frozen at -70 degrees C until analysis. Significance was defined as p<0.017.
Summary of Findings
Out of 52 analytes examined for mixing delay or elimination effects, the only statistically significant differences found were higher red blood cell counts and hematocrit in specimens inverted immediately compared to those rested 5 min before inversion, higher alanine aminotransferase and lower erythrocyte sedimentation rates in specimens inverted immediately compared to those not inverted, and lower red blood cell counts, hematocrit, and hemolysis index in specimens rested 5 min before inversion compared to those not inverted. Interestingly, sodium levels showed a clinically significant decrease (0.7%) when specimens were rested before inversion compared to those inverted immediately or those not inverted at all, but these differences were statistically insignificant. No other clinically relevant decreases were observed.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
FrozenNone (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeHematology/ auto analyzerProteinHematology/ auto analyzerGlycoproteinHematology/ auto analyzerMorphologyHematology/ auto analyzerCarbohydrateClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerCell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Biospecimen mixing Inverted 5 times after a 5 min rest in upright positionInverted 5 times immediately after collectionNot mixed