Skip to main content

Impact of blood volume, tube shaking, and incubation time on reproducibility of QuantiFERON-TB gold in-tube assay.

Gaur RL, Pai M, Banaei N

Publication: J Clin Microbiol (2013) • Vol 51 • Page 3521-6PMID: 23966505View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood volume, tube shaking, and duration of incubation on determination of tuberculosis (TB) response.

Conclusion

Significantly higher TB responses were measured when 0.8 mL of blood was assayed than when 1.0 or 1.2 mL was assayed, and this resulted in a higher sensitivity. Only 88.2% of the infected individuals with prior positive skin tests showed positive results using ELISA at the best volume (0.8 mL blood volume). Vigorous shaking of specimens led to significantly increased gamma interferon (IFN-gamma) levels in both nil (control) and QuantiFERON-TB Gold In-Tubes (QFT-GIT) compared to gentle inversion, but TB responses (the nil results subtracted from the QFT-GIT results) were only significantly altered if the response was calculated using a QFT-GIT and a nil tube that were mixed in different ways. In general, incubation times at 37 degrees C of 16-24 h did not affect TB responses or proportions of positive results among specimens from infected or uninfected individuals.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood volume, tube shaking, and duration of incubation on the sensitivity and specificity of the IFN-gamma ELISA determination of TB response. In addition, the effects of drawing specimens directly into assay tubes on specimen volume were evaluated, and TB skin test results were compared with ELISA results. Specimens were obtained from 33 uninfected individuals and 17 individuals infected with latent tuberculosis. Specimens were collected in 10 mL Monoject tubes, and blood was transferred to QFT-GIT or nil tubes (control), but a subset of 30 specimens were collected directly into the QFT-GIT and nil tubes. The control conditions for QFT-GIT testing included a blood volume of 1.0 mL, gentle inversion of tubes 10 times, and incubation at 37 degrees C for 24 h. After these procedures (or experimental variations), plasma was separated and held at room temperature for up to 8 h before assaying.

Summary of Findings

The QFT-GIT and nil Vacutainer tubes were determined to have draw volumes of 0.785-1.0 mL and 0.810-1.010 mL, respectively. For specimens from uninfected volunteers, significantly higher TB responses were measured when 0.8 mL of blood was assayed than when 1.0 or 1.2 mL was assayed (p=0.03 and p=0.04, respectively), however, the percentage of positive results were not significantly different between blood volumes, although there was one false positive result at the 1.2 mL volume. For specimens from the 17 individuals with confirmed latent tuberculosis infection (positive skin test), significantly higher TB responses were also measured in 0.8 mL specimens than 1.0 or 1.2 mL specimens (p=0.002 and p<0.001, respectively), and the percentage of specimens with positive results was significantly lower for 1.2 mL specimens (10/17, 58.8%) than 0.8 mL specimens (15/17, 88.2%, p=0.05). Vigorous shaking of specimens led to significantly increased IFN-gamma levels in both nil tubes and QFT-GIT compared to gentle inversion (p<0.001 and p=0.004, respectively), but sensitivity and specificity of the TB responses (QFT-GIT levels - nil levels) were only significantly altered if the response was calculated using a QFT-GIT and a nil tube that were mixed in different ways. In general, incubation times at 37 degrees C of 16, 20, or 24 h did not affect TB responses or the sensitivity or specificity of the assay.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    ProteinELISA
    Cell count/volumeMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Latent tuberculosis
    Normal
    Biospecimen AcquisitionType of collection container/solution
    Monoject tube
    Nil Vacutainer
    QFT-GIT Vacutainer
    Biospecimen Aliquots and ComponentsAliquot size/volume
    0.8 mL
    1.0 mL
    1.2 mL
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    Gentle inversion 10 times
    Vigorous shaking for 10 s
    Analyte Extraction and PurificationIncubation duration/condition
    16 h
    20 h
    24 h
    ELISA SpecificTargeted peptide/protein
    IFN-gamma
    ELISA SpecificTechnology platform
    Skin test