Low volume tubes can be effective to reduce the rate of hemolyzed specimens from the emergency department.
Giavarina D
Purpose
The purpose of this paper was to determine the effects of using smaller tubes (decreased blood collection volume) on the incidence of hemolysis.
Conclusion
When specimens were collected in 2.5 mL tubes rather than 5.0 mL tubes, there was a reduction in the rate of specimen rejection for potassium measurement due to hemolysis from 8.7% (587/6,725) to 2.6% (505/19,318).
Studies (1)
Purpose
The purpose of this study was to determine the effects of using smaller tubes (decreased blood collection volume) on the incidence of hemolysis. The authors stated that specimens scoring 4 or more on the hemolysis index (0.50-2.00 g/L of cell-free hemoglobin) were rejected for potassium measurement and considered hemolyzed. 26,043 specimens were included in the study spanning 11 weeks of blood collection in 5.0 mL lithium heparin Vacuette tubes and 33 subsequent weeks of blood collection in 2.5 mL lithium heparin Vacuette tubes. The authors note that all specimens were sent through a 600 meter long pneumatic tube system.
Summary of Findings
When specimens were collected in 2.5 mL tubes rather than 5.0 mL tubes, there was a reduction in the rate of specimen rejection for potassium measurement due to hemolysis from 8.7% (587/6,725) to 2.6% (505/19,318).
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution 2.5 mL Vacuette5.0 mL VacuetteBiospecimen Aliquots and Components Aliquot size/volume 2.5 mL5.0 mL