Segments from red blood cell units should not be used for quality testing.
Kurach JD, Hansen AL, Turner TR, Jenkins C, Acker JP
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of method of RBC preparation and analyzing RBC segments rather than the main unit on markers of RBC quality during refrigerated storage. 12 RBC units were obtained from blood donors using each method and were stored at 1-6 degrees C in saline-adenine-glucose-mannitol (SAGM).
Summary of Findings
On day 5 of storage, RBCs obtained by whole blood filtration had higher spun hematocrit (p<0.001) and hemoglobin content (p<0.001) and lower ATP content (p=0.03) than RBCs obtained by the buffy coat method. On day 42 of storage, RBCs obtained by whole blood filtration had higher rates of hemolysis (p<0.001) and hemoglobin content (p<0.001) than RBCs obtained by the buffy coat method. Among RBCs that were obtained by the buffy coat method, on day 5 of storage, segments had higher rates of hemolysis (p<0.001), spun hematocrit (p<0.001), and hemoglobin content (p<0.001) and lower MCV (p<0.001) and ATP content (p<0.001) than units. Further, on day 42 of storage, buffy coat-obtained RBC segments had higher rates of hemolysis (p<0.001), spun hematocrit (p<0.001), hemoglobin content (p<0.001), MCH (p=0.002), and MCHC (p=0.048) and lower ATP content (p<0.001) than units. Among RBCs obtained by the whole blood filtration method, on segments had higher rates of hemolysis (p<0.001) and MCHC (p=0.002) and lower spun hematocrit (p<0.001), hemoglobin content (p<0.001), MCV (p<0.001), and ATP content (p=0.004) than units on day 5 of storage. Further, on day 42, whole blood filtration RBC segments had higher rates of hemolysis (p<0.001), MCHC (p<0.001), and MCH (p=0.046) and lower spun hematocrit (p<0.001), hemoglobin content (p<0.001), MCV (p<0.001) and ATP content (p<0.001) than units.
Biospecimens
FluidBloodCellRed Blood CellsPreservation Types
Other PreservativeDiagnoses
Not specifiedPlatforms
ProteinSpectrophotometryProteinHematology/ auto analyzerCell count/volumeHematology/ auto analyzerCell count/volumeSpectrophotometrySmall moleculeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot size/volume Blood segmentBlood unitBiospecimen Aliquots and Components Blood processing method Buffy coat methodWhole blood filtration methodStorage Storage duration 42 days5 daysStorage Type of storage container Blood segmentBlood unit