Randomized study of washing 40- to 42-day-stored red blood cells.

Bennett-Guerrero E, Kirby BS, Zhu H, Herman AE, Bandarenko N, McMahon TJ

Publication: Transfusion (2014) • Vol 54(10) • Page 1362544-52PMID: 24735194View on PubMed

Purpose

The purpose of this paper was to determine the effects of washing method on markers of red blood cell (RBC) quality and RBC fragility in RBCs refrigerated for 40-42 days.

Conclusion

Compared to unwashed RBCs, washing RBCs with the Cell Saver Elite decreased hematocrit (Hct), glucose, lactate, potassium and CD235 negative microparticles and increased volume, cell free volume, hemoglobin saturation, hemolysis, total free hemoglobin, RBC microparticles and CD235 positive microparticles, but washing with the COBE 2991 only decreased CD235 negative microparticles. Comparing the two washing methods, specimens washed with the COBE 2991 had higher Hct, total free hemoglobin, lactate and potassium and lower glucose levels, hemoglobin saturation, hemolysis, volume, RBC microparticles, and cell free volume than those washed with Cell Saver Elite, but RBC recovery was not affected by the method of washing. after ATP levels and susceptibility to stress-induced hemolysis (agitation or filtration) were not significantly affected by washing or method of washing.

Studies (1)

Purpose

The purpose of this study was to determine the effects of washing method on markers of RBC quality and RBC fragility in RBCs refrigerated for 40-42 days. 40 RBC units stored 40-42 days were obtained from the American Red Cross and analyzed immediately, and then 20 units each were washed with the COBE2991 or the Cell Saver Elite.

Summary of Findings

Compared to unwashed RBCs, washing with the Cell Saver Elite decreased Hct (p<0.05), glucose (p<0.05), lactate (p<0.05), potassium (p<0.05), and CD235 negative microparticles and increased volume (P<0.05), cell free volume (P<0.05), hemoglobin saturation (p<0.05), hemolysis (p<0.05), total free hemoglobin (p<0.05), CD235 positive microparticles (p<0.05) and RBC microparticles, but washing only reduced the number of CD235 negative microparticles (p<0.05). Comparing the two washing methods, specimens washed with the COBE 2991 had higher Hct (p<0.05), total free hemoglobin (p<0.05), lactate (p<0.05) and potassium (p<0.05) and lower glucose levels (p<0.05), hemoglobin saturation (p<0.05), hemolysis (p<0.05), volume (p<0.05), RBC microparticles (p<0.05), CD235 positive microparticles (p<0.05) and cell free volume (p<0.05) than specimens washed with the Cell Saver Elite, but RBC recovery was not affected by the method of washing. ATP levels and susceptibility to stress-induced hemolysis (agitation or filtration) were not significantly affected by washing or method of washing.

  • Biospecimens

    CellRed Blood Cells
  • Preservation Types

    Other Preservative
  • Diagnoses

    Normal
  • Platforms

    Small moleculeEnzyme assay
    Small moleculeClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinSpectrophotometry
    Cell count/volumeSpectrophotometry
    Cell count/volumeFlow cytometry
    CarbohydrateClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood processing method
    Unwashed
    Washed with COBE 2991
    Washed with Cell Saver Elite
    Analyte Extraction and PurificationWashing
    Unwashed
    Washed with COBE 2991
    Washed with Cell Saver Elite