Purpose

The purpose of this paper was to determine the effects of collection media and extraction method on RNA quality, yield, and performance in microarray analysis using cervical specimens.

Conclusion

The collection media that afforded the highest yields of RNA, regardless of extraction method, was PAXgene Stabilizer followed by PreservCyt. Using RNAlater, 95% ethanol, or high salt MTM (RNAwiz extraction only) as collection media failed to yield RNA with discernable ribosomal bands. RNA from cervical cells collected in PAXgene stabilizer were the only samples with intact 28S RNA visible on a gel. Generally, MasterPure extraction gave superior RNA yields compared to RNAwiz extraction. RNA from specimens collected in PreservCyt had higher average raw intensity and lower background after microarray hybridization than RNA obtained from specimens placed in PAXgene Stabilizer, but both of these types of collection media yielded RNA that gave reproducible microarray results.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection media and extraction method on RNA quality, yield, and performance in microarray analysis using cervical specimens. A total of 378 specimens were stored in collection media for 24 h at room temperature, transported to the laboratory (details not provided), and then stored for an additional 24-48 h at 4 degrees C prior to RNA extraction. Cells collected in PAXgene Stabilizer underwent an extra wash step in dimethylpyrocarbinate (DMPC)-treated water before pelleting while all other specimens were pelleted without this wash step. Comparisons were made across all solution types (preservatives and cell culture media). While the manufacturer recommended protocol was used for RNAwiz extraction, proteinase K concentration was increased to 200 ug/sample and lysis was performed at 60 degrees C for 50 minutes for MasterPure Complete DNA and RNA Purification Method.

Summary of Findings

The collection media that afforded the highest yields of RNA, regardless of extraction method, was PAXgene Stabilizer followed by PreservCyt. Smaller RNA yields were obtained from specimens collected into tissue culture media (DMEM, F-12, AIM-V, keratinocyte serum-free media, and organ transport medium), regardless of extraction method, or collected into high salt MTM and extracted by MasterPure. Using RNAlater, 95% ethanol, or high salt MTM (RNAwiz extraction only) as collection media failed to yield RNA with discernable ribosomal bands. Interestingly, RNA from cervical cells collected in PAXgene stabilizer were the only samples with intact 28S RNA visible on a gel, while the rest of the samples showed a truncated version. Generally, MasterPure extraction gave superior RNA yields compared to RNAwiz extraction. RNA from specimens collected into PreservCyt had 3-fold higher average raw intensity and lower background after microarray hybridization than specimens collected into PAXgene stabilizer (5-7% and 11-14%, respectively). Both of these types of collection media yielded RNA that gave reproducible microarray results.

  • Biospecimens

    CellCervix
  • Preservation Types

    RNAlaterEthanolOther Preservative
  • Diagnoses

    Not specified
  • Platforms

    RNADNA microarray
    RNAElectrophoresis
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Ethanol
    PreservCyt
    RNAlater
    StorageShort-term storage solution
    AIM-V
    DMEM
    F-12
    Keratinocyte serum-free media
    MTM
    Organ transport medium
    PAXgene Stabilizer
    Analyte Extraction and PurificationAnalyte isolation method
    MasterPure