Preanalytical study of fetuin-A: effect of sample type, processing speed and freeze-thaw cycles.

McArthur L, Johnston L, Sattar N, Logue J, Welsh P

Publication: Ann Clin Biochem (2015) • Vol 52 • Page 165-8PMID: 24696154View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed centrifugation, freeze-thaw cycling, and analyzing plasma rather than serum on levels of fetuin-A.

Conclusion

Fetuin-A concentrations were comparable in plasma and serum obtained from blood centrifuged 2 h after collection. However, when blood was stored at room temperature for 48 h before centrifugation, levels of fetuin-A in plasma were significantly higher than when blood was centrifuged within 2 h of collection, but levels of fetuin-A in serum were not affected by delayed centrifugation. Subjecting plasma or serum to 3 freeze-thaw cycles rather than just 1 did not affect fetuin-A measurement.

Studies (1)

Purpose

The purpose of this paper was to determine the effects of a 2 or 48 h delay in centrifugation, freeze-thaw cycling, and analyzing plasma rather than serum on levels of fetuin-A. Blood was obtained from 19 healthy patients in K2EDTA or clot activator tubes and stored at room temperature for 2 or 48 h before centrifugation. After centrifugation, plasma and serum were stored at -80 degrees C. Specimens were thawed at room temperature for 1 h prior to measurement.

Summary of Findings

Fetuin-A concentrations were comparable in plasma and serum obtained from blood centrifuged 2 h after collection. However, when blood was stored at room temperature for 48 h before centrifugation, levels of fetuin-A in plasma were higher than when blood was centrifuged within 2 h of collection (p<0.0005), but levels of fetuin-A in serum were not affected by delayed centrifugation. Subjecting plasma or serum to 3 freeze-thaw cycles rather than just 1 did not affect fetuin-A measurements.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageFreeze/thaw cycling
    1 cycle
    3 cycles
    StorageTime at room temperature
    2 h
    48 h