Sources of pre-analytical variations in yield of DNA extracted from blood samples: analysis of 50,000 DNA samples in EPIC.
Caboux E, Lallemand C, Ferro G, Hémon B, Mendy M, Biessy C, Sims M, Wareham N, Britten A, Boland A, Hutchinson A, Siddiq A, Vineis P, Riboli E, Romieu I, Rinaldi S, Gunter MJ, Peeters PH, van der Schouw YT, Travis R, Bueno-de-Mesquita HB, Canzian F, Sánchez MJ, Skeie G, Olsen KS, Lund E, Bilbao R, Sala N, Barricarte A, Palli D, Navarro C, Panico S, Redondo ML, Polidoro S, Dossus L, Boutron-Ruault MC, Clavel-Chapelon F, Trichopoulou A, Trichopoulos D, Lagiou P, Boeing H, Fisher E, Tumino R, Agnoli C, Hainaut P
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of patient characteristics (age, BMI, gender, smoking status), timing of blood collection relative to cancer diagnosis, processing delays and extraction technique on the DNA yield from frozen buffy coat specimens. The study used a cohort of 52,256 blood specimens from 19 centers throughout Europe representing many different sub-studies on disease (cancer, heart disease, diabetes) genetics. Specimens were collected into monovette tubes containing anticoagulant (unspecified), and buffy coats were obtained by centrifugation. To each 2 mL aliquot of buffy coat, 0.5 mL of physiological solution was added, and the specimens were split and stored in straws which were stored frozen for an unspecified duration until DNA extraction.
Summary of Findings
Significantly more DNA was obtained when specimens were stored in 2 straws rather than just 1 (p<0.01), from females than males (p<0.01), from smokers than non-smokers (p<0.01), using the automated LS1 than the LS2 or manual extraction (p<0.01, both) and from specimens without visible hemolysis than those with hemolysis (p<0.01). Further, the DNA yield was higher when quantified using Picogreen than Nanodrop (p<0.01), and the authors report this difference was larger when DNA was obtained from 1 straw rather than 2. More DNA was obtained from individuals who had cancer than those without (p<0.01), but there was no associated effect of cancer type. However, there was no effect of having previously been diagnosed with cancer or being diagnosed after the blood on DNA yield. DNA yield decreased with older patient age (p<0.01) and higher levels of specimen hemolysis (p<0.01), lower BMI (p<0.01), longer time between blood draw and refrigeration (p=0.02) and longer time between refrigeration and centrifugation (p<0.02). However, DNA yield was not affected by the time from centrifugation to freezing. DNA yield varied significantly between the 19 centers (p<0.01), and this variance accounted for 16.9% of the total variance in DNA yield. Importantly, insufficient DNA yield or concentration was the main reason specimens could not be used further for genotyping.
Biospecimens
FluidBuffy CoatFluidBloodPreservation Types
FrozenDiagnoses
Diabetes Type 2NeoplasticCarcinomaNeoplasticLymphomaNeoplasticCardiovascular DiseasePlatforms
DNAFluorometryDNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Current cancer diagnosisFuture cancer diagnosisNo diagnosis of cancerPrior cancer diagnosisPreaquisition Other drugs Former smokerNon-smokerSmokerPreaquisition Patient age 45-49 years50-54 years55-59 years60-64 years<45 years>65 yearsPreaquisition Patient body mass index 25-27.527.5-3030-35<25>35Preaquisition Patient gender FemaleMaleBiospecimen Acquisition Locale of biospecimen collection 19 centers throughout EuropeBiospecimen Acquisition Time of biospecimen collection After cancer diagnosisPrior to cancer diagnosisBiospecimen Aliquots and Components Aliquot size/volume 1 straw2 strawsBiospecimen Aliquots and Components Hemolysis AbsentPresentStorage Storage duration 1-2 h1-3 h1.5-2 h2-6 h45-59 min5 min-1 h<1.5 h<45 min<5 min> 3 h>2 h>6 hAnalyte Extraction and Purification Analyte isolation method Autopure LS1 DNA extraction systemAutopure LS2 DNA extraction systemManual extractionSpectrophotometry Specific Technology platform NanodropPicogreen