Comparison of blood RNA extraction methods used for gene expression profiling in amyotrophic lateral sclerosis.

Bayatti N, Cooper-Knock J, Bury JJ, Wyles M, Heath PR, Kirby J, Shaw PJ

Publication: PLoS One (2014) • Vol 9 • Page e87508PMID: 24475299View on PubMed

Purpose

The purpose of this paper was to compare gene expression profiling between specimens in the PAXgene (PAX), TEMPUS (TEM), and LEUKOLOCK (LL) blood collection and RNA extraction systems, and to determine the utility of globin depletion with GlobinClear (GC).

Conclusion

The TEM system (combined with globin depletion) and the LL system for blood collection and RNA extraction were generally superior to the PAX system (combined with globin depletion and necessary DNase treatment), giving higher RNA yields, higher RNA integrity number (RIN) values, more consistent array performance, and similar real time qRT-PCR validation of array results.

Studies (1)

Purpose

The purpose of this study was to compare gene expression profiling between specimens in the PAX, TEM, and LL blood collection and RNA extraction systems, and to determine the utility of globin depletion with GlobinClear. Specimens were obtained from 8 sporadic amyotrophic lateral sclerosis (ALS) patients and 7 healthy volunteers. PAX and TEM systems use their own collection tubes, but specimens intended for LL processing were collected into K2EDTA tubes, passed through LL filter, and RNAlater was added. All specimens were frozen at -20 degrees C until analysis.

Summary of Findings

The highest quantity of RNA was extracted using the TEM system, followed by the PAX system, and lastly, the LL system. TEM and LL-extracted RNA showed high quality (RIN >7.0) without DNase treatment. However, PAX-extracted RNA needed to undergo DNase treatment before high quality RNA was obtained. This DNase treatment also decreased the yield of RNA from PAX-extracted specimens. Further, globin mRNA depletion by GC lowered the RIN values for PAX-extracted RNA (PAX RIN=7.9, PAX GC RIN=7.2) but not for TEM-extracted RNA (both RIN=7.9). In general, PAX RNA array hybridizations showed the most variability. GC treatment increased the microarray percent present calls for PAX and TEM-extracted RNA from 39% and 43%, respectively, to 50% for each, the same as LL-extracted RNA. In addition, globin clearance unmasked transcripts that were otherwise not detected (6022 probe sets). The PAX GC RNA and TEM GC RNA had more differentially-regulated probe sets between ALS patients and healthy controls in common than either did with LL RNA. For both TEM GC specimens and LL specimens, 4 out of 6 genes chosen for validation of differential expression between ALS patients and healthy controls were indeed validated. The authors report that PAX GC specimens were not used for validation due to the longer preparation time required.

  • Biospecimens

    FluidBlood
  • Preservation Types

    FrozenPAXgeneOther Preservative
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    RNADNA microarray
    RNAReal-time qRT-PCR
    RNAAutomated electrophoresis/Bioanalyzer
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Amyotrophic lateral sclerosis
    Healthy
    Biospecimen AcquisitionType of collection container/solution
    K2EDTA Vacutainer
    PAXgene collection tube
    TEMPUS collection tube
    Analyte Extraction and PurificationAnalyte isolation method
    LL
    PAX
    TEM
    Analyte Extraction and PurificationAnalyte purification
    Globin depletion
    No globin depletion
    Analyte Extraction and PurificationNucleic acid digestion
    DNase treatment
    No DNase treatment