The purpose of this paper was to determine the effects of storage temperature, storage headspace, sealing of vials, and freeze-thaw cycling on oxidized albumin and apolipoprotein A-I (ApoA-I) in plasma. Levels of oxidized albumin and apoA-I in plasma were also compared with those in serum.
Elevated Plasma Albumin and Apolipoprotein A-I Oxidation under Suboptimal Specimen Storage Conditions.
Borges CR, Rehder DS, Jensen S, Schaab MR, Sherma ND, Yassine H, Nikolova B, Breburda C
Purpose
Conclusion
Albumin and apoA-I underwent oxidation over time when plasma was stored at -20 degrees C or higher. However, storage of plasma at -80 degrees C prevented oxidation for at least 300 days. While storage of plasma in an automatically defrosted -20 degrees C freezer caused dehydration, there were no differences in analyte oxidation rates compared to those measured in specimens stored in a manually defrosted freezer. Albumin and apoA-I oxidation in plasma were not affected by the type of storage container, degree of vial sealing, patient diagnosis (healthy versus diabetic), patient gender, or analysis of serum versus EDTA plasma. Twenty freeze-thaw cycles, with freezing occurring at -80 degrees C, led to a small increase in the amount of albumin oxidation in plasma but no increase in the degree of apoA-I oxidation (initially 0 and remaining there). Opening versus not opening the vials during the thaw cycles had no effect on analyte oxidation in plasma. Albumin oxidation during room temperature storage of plasma was not affected by surface area to volume ratio. On the other hand, apoA-I oxidation happened more rapidly in the larger plasma aliquots than the smaller ones.
Studies (1)
Purpose
The purpose of this study was to determine the effects of patient gender, storage temperature, storage headspace, aliquot size, sealing of vials, and freeze-thaw cycling on oxidized albumin and apoA-I in plasma. Levels of oxidized albumin and apoA-I in plasma were also compared with those in serum. Blood was collected from healthy volunteers as well as patients diagnosed with either type 2 diabetes, prostate cancer or an acute myocardial infarction. Blood was processed immediately, and serum and plasma were stored at -80 degrees C and/or -70 degrees C until shipping on dry ice before analysis, with the exception of specimens intended for surface area-to-volume ratio analysis and those used for frozen and room temperature time course experiments, which were analyzed fresh. For most experiments, plasma aliquots from a single donor were used.
Summary of Findings
Leaving diluted plasma in the autosampler at 10 degrees C led to apoA-I oxidation after approximately 5 hours, while albumin oxidation was stable in plasma during storage for at least 16 hours. The addition of 5 mM MetSer did not inhibit the oxidation of apoA-I in diluted plasma stored at 10 degrees C. Albumin and apoA-I underwent oxidation when undiluted plasma was stored at -20 degrees C or room temperature, but each was stable at -80 degrees C for at least 300 days, and oxidation occurred faster at room temperature than at -20 degrees C. Neither storage of plasma in a manually defrosted freezer rather than an automatically defrosted freezer (both -20 degrees C) nor the type of storage container or degree of vial sealing affected analyte oxidation. However, storage of plasma in an automatically defrosted freezer caused specimen dehydration, regardless of storage container. There were no notable differences in apoA-I or albumin oxidation during -20 degrees C storage between plasma from a healthy volunteer and one with poorly controlled diabetes. Twenty freeze-thaw cycles, with freezing occurring at -80 degrees C, led to a small increase in the amount of albumin oxidation in plasma but no increase in the degree of apoA-I oxidation (initially 0 and remaining there). Opening versus not opening the vials during the thaw cycles had no effects on analyte oxidation. Neither patient gender nor analysis of serum versus EDTA plasma affected apoA-I or albumin oxidation measurements. Albumin oxidation over time was not affected by surface area to volume ratio when fresh aliquots of 10, 100, 200, and 400 uL plasma were stored at room temperature. On the other hand, apoA-I oxidation happened more rapidly in the larger aliquots than the smaller ones, with levels first detectable and significantly different between all volumes after 11 days (p<0.01).
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
FrozenNone (Fresh)Diagnoses
Diabetes Type 2NormalNeoplasticCarcinomaCardiovascular DiseasePlatforms
ProteinLC-ESI-MS/MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition HealthyMyocardial infarctionPoorly controlled type 2 diabetesProstate cancerPreaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Aliquot size/volume 10 uL100 uL200 uL400 uLBiospecimen Aliquots and Components Biospecimen components 5 mM MetSer addedNo added MetSerBiospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Freeze/thaw cycling 1 cycle20 cyclesStorage Storage conditions Automatically defrosted freezerDilutedManually defrosted freezerUndilutedStorage Storage duration 0 d0-1200 min0-300 days1 d11 d18 d25 d3 dStorage Storage temperature -20 degrees C-80 degrees C10 degrees CRoom temperatureStorage Thaw temperature/condition With caps off during thawWith caps on during thawStorage Type of storage container 1.5 mL Eppendorf snap-cap tube with a hole punched in the top1.5 mL Eppendorf snap-cap tube with no hole2.0 mL conical tube with inner threaded screw cap and sealing o-ring