Skip to main content

Influence of plasma processing on recovery and analysis of circulating nucleic acids.

Page K, Guttery DS, Zahra N, Primrose L, Elshaw SR, Pringle JH, Blighe K, Marchese SD, Hills A, Woodley L, Stebbing J, Coombes RC, Shaw JA

Publication: PLoS One (2013) • Vol 8 • Page e77963PMID: 24205045View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed centrifugation, centrifugation speed, extraction method, frozen storage and array platform on circulating free DNA (cfDNA) and microRNA (miRNA) yield and quantification in plasma.

Conclusion

miRNA yield was highest when extracted with the miRNeasy Serum/Plasma kit, and cfDNA yield was highest when extracted using the QIAamp DNA Blood Mini or CNA kits, but recovery of small cfDNA fragments was more common using the QIAamp circulating nucleic acid (DCNA) kit. miRNA yield was not affected by the volume of plasma used or delayed centrifugation, but levels of 6 miRNAs were significantly affected by delayed centrifugation. When the second centrifugation speed was increased from 1000 x g, the number of miRNAs detected decreased, but there was no effect on the yield of GAPDH or the relative cycle threshold (CT) values of most of the miRNAs. Fewer miRNAs were detected in pooled plasma that was stored for >12 years at -80 degrees C than in freshly frozen plasma. miRNA levels were only modestly correlated between the two low density array platforms.

Studies (2)

Purpose

The purpose of this study was to determine the effect of cfDNA extraction method and centrifugation speed on the yield of amplifiable DNA and deep sequencing results in plasma. The effect of DNA extraction method on cfDNA yield was determined using pooled plasma from 3 healthy donors. To determine the effect of extraction method on deep sequencing results, venous blood from 4 patients with metastatic breast cancer was drawn into EDTA tubes and centrifuged at 1000 x g for 10 min at 4 degrees C, and plasma was removed. Plasma was centrifuged at 1000 x g (or 2000 x g, or 10000 x g) for 10 min and stored at -80 degrees C.

Summary of Findings

There was no effect of the speed of the second centrifugation step on the CT of GAPDH. cfDNA yield, as determined by real-time PCR, was highest when cfDNA was extracted from the single plasma pool using the QIAamp DNA Blood Mini or CNA kits, with 1/10 as much cfDNA obtained using the NucleoSpin Plasma XS Kit or the FitAmp Plasma/Serum DNA Isolation kit. Recovery of a 23 kb fragment of spiked DNA was comparable between the two QIAamp kits, but recovery of a 564 bp fragment was highest using the QIAamp CNA kit. Overall, the number of deep sequencing reads for cfDNA isolated using the two QIAgen kits was very strongly correlated (r>0.95), but in one specimen, the correlation was strong (r=0.87) with more uniform coverage observed using cfDNA isolated with the QIAamp CNA kit. Of the 167 sequence variants identified, 136 were identified at a similar rate using cfDNA isolated with either kit, and 31 were identified using only one kit, and these generally were detected with fewer reads.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    NeoplasticCarcinoma
    Normal
  • Platforms

    DNAReal-time qPCR
    DNANext generation sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Multiple speeds compared
    Analyte Extraction and PurificationAnalyte isolation method
    FitAmp Plasma/Serum DNA Isolation kit
    NucleoSpin Plasma XS Kit
    QIAamp DNA Blood Mini kit
    QIAamp circulating nucleic acid kits
    Real-time qPCR SpecificTargeted nucleic acid
    Beta actin
    GAPDH
    HPRT1