The purpose of this paper was to determine the effect of storing platelets (Plts) in 65% Plt additive solution Isoplate (PAS-F) rather than in 100% plasma when there is a 24 h suspension of agitation.
Maintenance of the in vitro storage properties of apheresis platelets suspended in PAS-F after a 24-hour interruption of agitation.
Wagner SJ, Seetharaman S, Cook T
Purpose
Conclusion
Significant detrimental effects of storing Plts in PAS-F rather than plasma were observed for glucose utilization, bicarbonate neutralization, pH, partial pressure carbon dioxide (PCO2), partial pressure oxygen (PO2) the percentage of DHE, CD62P, CD42b and JC-1 positive Plts, hypotonic shock response (HSR), the percentage of Plts that were discoid, extent of shape change (ESC), and 5-chloromethyl-2′,7′-dichlorodihydrofluorescein diacetate acetyl ester (CM-H2DCFDA) fluorescence. Plt storage solution did not affect Plt count, swirling, Plt aggregation, or annexin V binding. With storage, pH, aggregation and the percentage of discoid Plts declined, pO2 and the percentage of Annexin V positive Plts increased, and pCO2 increased and then decreased again.
Studies (1)
Purpose
The purpose of this study was to determine the effect of storing Plts at room temperature for 6 days in 65% PAS-F rather than in 100% plasma when agitation is suspended between days 2 and 3. Hyperconcentrated apheresis Plts from 12 individuals were divided to create 2 identical units. Plasma was added to one unit (100% plasma), and PAS-F was added to the other to create a unit in 65% PAS-F, 35% plasma. Plts were stored at 20-24°C with agitation between days 1-2, and 3-6.
Summary of Findings
Glucose utilization and bicarbonate neutralization were lower in Plts stored in 65% PAS-F than in Plts stored in 100% plasma. pH and PCO2 were lower, and the percentage of DHE positive Plts was higher in Plts stored in 65% PAS-F than in Plts in 100% plasma at all timepoints (p<0.05). Further, the percentage of Plts that were discoid and ESC were lower, and the percentage of Plts expressing CD62P was higher on day 3 and day 6 in Plts stored in 65% PAS-F than those stored in plasma. HSR and the percentages of CD42b and JC1 positive Plts were lower, and PO2 was higher on day 3 in Plts stored in 65% PAS-F than those stored in 100% plasma, and CM-H2DCFDA fluorescence was higher in Plts stored in 65% PAS-F than those stored in plasma on day 2, but was also highly variable. Plt storage solution did not affect Plt count, swirling, Plt aggregation, or annexin V binding. With storage, pH, aggregation and the percentage of discoid Plts declined, pO2 and the percentage of Annexin V positive Plts increased, and PCO2 increased and then decreased again.