Multiplex PCR with minisequencing as an effective high-throughput SNP typing method for formalin-fixed tissue.

Gilbert MT, Sanchez JJ, Haselkorn T, Jewell LD, Lucas SB, Van Marck E, Børsting C, Morling N, Worobey M

Publication: Electrophoresis (2007) • Vol 28 • Page 2361-7PMID: 17578837View on PubMed

Purpose

The purpose of this paper was to determine the effects of DNA extraction method and DNA quality on multiplex PCR with minisequencing (MPMS) success rates using archival formalin-fixed paraffin-embedded (FFPE) spleen and lung autopsy specimens.

Conclusion

The authors report no effect of extraction method on multiplex PCR success. Further, the authors report no variation in genotyping results between replicates of the same specimen. Among the three specimens with maximum amplicon sizes of 112, there was a weak to modest inverse correlation between fragment size and genotyping success, but this was not observed with more intact specimens. The authors state that the MPMS success rate was correlated with the maximum amplicon size and DNA yield, and it was modestly inversely correlated with cycle threshold (CT) value. As expected, given the differing rates of PCR failures, there were significant variations between the 6 specimens in MPMS success rates.

Studies (1)

Purpose

The purpose of this study was to determine the effects of DNA extraction method and DNA quality on MPMS success rates using archival FFPE spleen and lung autopsy specimens. Specimens were stored 9-24 years, and details of specimen processing were unknown. The 6 specimens (2 lung, 4 spleen) were selected based on high or low quality of DNA from an initial set of 23 specimens. DNA was extracted using the QIAamp DNA micro kit or using organic extraction. Different specimens yielded different numbers of replicates ranging from 3-35, and thus the data over-represents 2 specimens (contributing 23 and 35 extractions) and under-represents the other 4 (contributing 3, 6, 12 and 13 specimens). The two specimens contributing the highest number of extractions also yielded the maximum amplicon size and lowest CT value.

Summary of Findings

The authors report no effect of extraction method on multiplex PCR success. Further, the authors report no variation in genotyping results between replicates of the same specimen. In the three specimens with maximum amplicon sizes of 112, there was a weak to modest inverse correlation between fragment size and genotyping success (r2=0.35-0.42), but this was not observed with more intact specimens, and the data did not decrease linearly. The authors state that the minisequencing success rate was correlated with the maximum amplicon size and DNA yield (no r2 values presented) and inversely correlated with CT value (r2=0.53). As expected, given the differing rates of PCR failures, there were significant variations between the 6 specimens in MPMS success rates (p<0.0001).

  • Biospecimens

    TissueSpleen
    TissueLung
  • Preservation Types

    Formalin
  • Diagnoses

    Autopsy
  • Platforms

    DNASNP assay
    DNADNA sequencing
    DNAReal-time qPCR
    DNASpectrophotometry
    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Organic extraction
    QIAamp DNA micro kit
    PCR SpecificLength of gene fragment
    112 bp
    218 bp
    240 bp
    390 bp
    PCR SpecificTargeted nucleic acid
    Amelogenin
    Near MX1 gene
    PECAM gene Intron 9-10
    Real-time qPCR SpecificTargeted nucleic acid
    Amelogenin