Skip to main content

Gene expression analysis using long-term preserved formalin-fixed and paraffin-embedded tissue of non-small cell lung cancer.

Jacobson TA, Lundahl J, Mellstedt H, Moshfegh A

Publication: Int J Oncol (2011) • Vol 38 • Page 1075-81PMID: 21305253View on PubMed

Purpose

The purpose of this paper was to determine the effects of RNA extraction method from formalin-fixed paraffin-embedded (FFPE) non-small cell lung cancer (NSCLC) specimens on cycle threshold (CT) values and the effect of whole transcriptome amplification method on the correlation in expression between FFPE and frozen NSCLC specimens.

Conclusion

While there was no effect of RNA extraction method on CT values when 20 ng of DNA was used as the input, CT values for 100 ng were significantly lower for specimens extracted using the RecoverAll Kit than the HighPure FFPE RNA micro kit or the RNeasy FFPE kit. The gene expression profile of Nugen amplified cDNA from FFPE specimens showed that 23%, 35% and 55% of transcripts were altered by more than 2-fold from those amplified from frozen specimens using the Nugen V2, Nugen Pico, and Affymetrix standard protocols, respectively, and for 14 of 16 genes (88%), the >2-fold change in expression was confirmed by real-time qPCR. In frozen specimens, the correlations of expression for endogenous control genes between Affymetrix amplified and Nugen V2 or Nugen Pico amplified specimens were r=0.91 and r=0.88, respectively, while the correlation between frozen Nugen V2 amplified specimens and Nugen Pico amplified FFPE specimens was r=0.71. Importantly, expression of 2 of 15 previously identified NSCLC genes differed between amplification methods.

Studies (2)

Purpose

The purpose of this study was to determine the effects of RNA extraction method and template amount on CT values for FFPE NSCLC specimens. Specimens were stored for 20 years prior to the study.

Summary of Findings

RNA extraction method had no effect on CT values when 20 ng of DNA was used as the input. However, when 100 ng of template DNA was added to the amplification reaction, CT values were significantly lower for specimens extracted using the RecoverAll Kit than the HighPure FFPE RNA micro kit or the RNeasy FFPE kit (both p<0.005). As expected, regardless of RNA extraction method, CT values were significantly lower when 100 ng was used instead of 20 ng (p<0.005).
  • Biospecimens

    TissueLung
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    QIAgen RNeasy FFPE kit
    Ambion RecoverAll Kit
    Roche HighPure FFPE RNA micro kit
    Real-time qRT-PCR SpecificTemplate/input amount
    20 ng