Influence of spurious hemolysis on blood gas analysis.
Lippi G, Fontana R, Avanzini P, Sandei F, Ippolito L
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of mechanically induced hemolysis on blood gas analysis. Venous blood specimens were obtained from 9 volunteers and collected into sodium heparin tubes. Hemolysis index was measured in plasma while 13 other analytes were evaluated in whole blood on a blood gas analyzer.
Summary of Findings
Aspiration of anticoagulated whole blood through a 30 gauge needle led to significantly increased cell-free hemoglobin, pCO2 (4.1%), HCO3- (1.4%), and potassium (152%) levels while pH (-0.2%), pO2 (-4.9%), sO2 (-4.9%), COHb (-11%), and Ca2+ (-7.0%) levels were significantly lower in the hemolyzed than non-hemolyzed specimens. Clinically significant changes were observed in the hemolyzed specimens for pO2, pCO2, Ca2+, and potassium. Hemoglobin, ABE, and MetHb were not significantly affected by hemolysis.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeSpectrophotometryElectrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaWhole bloodBiospecimen Aliquots and Components Hemolysis Fine needle aspiration-inducedNot induced