Evaluation of formalin-free tissue fixation for RNA and microRNA studies.

Arzt L, Kothmaier H, Quehenberger F, Halbwedl I, Wagner K, Maierhofer T, Popper HH

Publication: Exp Mol Pathol (2011) • Vol 91 • Page 490-5PMID: 21641900View on PubMed

Purpose

The purpose of this paper was to determine the effects of fixative type on RNA yield and quality from 10 paraffin-embedded lung tumor specimens. The effects of storage duration and extraction parameters on RNA yield and purity from two formalin-fixed and paraffin-embedded (FFPE) lung tumor specimens were also examined.

Conclusion

While RNA yield and RNA integrity numbers (RIN) were comparable between the 4 fixative types, RNA purity was lower from FFPE specimens than RCL-2, HOPE or FineFix specimens, and maximum fragment length was dependent on fixative. The yield of microRNA (miRNA) was higher from FineFix-fixed specimens than HOPE- (p=0.032) or RCL-2-fixed specimens, and it was higher from HOPE-fixed than RCL-2-fixed specimens. Fixative type also affected normalized real-time qPCR measurements of miR-106a and miR-155. The RNA yield from FFPE specimens decreased with storage but increased when proteinase K digestion was lengthened. The RNeasy kit yielded more RNA from FFPE specimens and did a better job at removing the chemical contaminants than the RecoverAll kit. Additional purification with the Turbo DNA-free kit did not improve the RNA purity and reduced yield from FFPE specimens.

Studies (2)

Purpose

The purpose of this study was to determine the effects of fixative type on the yield, purity and quality of RNA from 10 paraffin-embedded lung cancer specimens. From each specimen, 4 adjacent tissue samples were obtained and fixed in formalin, HOPE, FineFix, or RCL-2 and paraffin-embedded. Blocks were stored at 4 degrees C until sectioning. RNA was extracted from 3-10 4 um sections shown by H%E staining to be composed of 85% tumor cells.

Summary of Findings

While RNA yield was comparable between the 4 fixative types, the purity of the RNA was lower from FFPE specimens than RCL-2-, HOPE- or FineFix-fixed specimens (p<0.001). Further, while the average RIN was 2.1-2.5 for all fixatives, fragments of 2000 bp were obtained from HOPE-fixed specimens, but fragments from RCL-2-fixed specimens had a maximum size of 500 bp, and those from formalin and FineFix-fixed specimens were generally <200 bp. The yield of miRNA was higher from FineFix-fixed specimens than HOPE- (p=0.032) or RCL-2-fixed specimens (p=0.0005), and HOPE-fixed specimens had a higher miRNA yield than RCL-2-fixed specimens (p=0.005). Fixative type affected normalized real-time qPCR measurements of miR-106a (p=0.00003) and miR-155 (p=0.003), and pairwise comparisons showed more miR106a in FineFix-fixed than HOPE-fixed specimens.

  • Biospecimens

    TissueLung
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    RNASpectrophotometry
    RNAAutomated electrophoresis/Bioanalyzer
    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    FineFIX
    Formalin (buffered)
    HOPE
    RCL2
    Real-time qRT-PCR SpecificTargeted nucleic acid
    miR-106a
    miR-155