Skip to main content

In vitro mutation artifacts after formalin fixation and error prone translesion synthesis during PCR.

Quach N, Goodman MF, Shibata D

Publication: BMC Clin Pathol (2004) • Vol 4 • Page 1PMID: 15028125View on PubMed

Purpose

The purpose of this paper was to determine the effects of formalin fixation and fixation duration on PCR yield, maximum amplicon size and the number of mutations identified.

Conclusion

Increasing fixation duration led to decreasing PCR yield and decreased success in amplifying longer fragments. Fixed specimens had 3-4 fold more mutations than fresh specimens, but the number of mutations identified was not affected by fixation duration or fragment size. 92% of the mutations identified in fixed specimens were transition mutations, and 6.6% were small deletions or additions. Mutations were more likely to occur at AT pairs than GC pairs. The mutations identified were scattered evenly throughout the gene fragments. The authors report that using AmpliTaq gold rather than AmpliTaq increased PCR yields but did not affect mutation rates.

Studies (1)

Purpose

The purpose of this study was to determine the effects of formalin fixation and fixation duration on PCR yield, maximum amplicon size and the number of mutations identified. Normal adjacent colon from a patient with adenocarcinoma was analyzed fresh or fixed in formalin for 1-7 days and paraffin embedded. Sections were deparaffinized with ClearRight 3, digested for 4 h in proteinase K at 56 degrees C, and boiled for 5 min in digestion buffer. DNA from fresh tissue was extracted using the DNeasy kit. DNA was cloned into the TOPO vector before sequencing.

Summary of Findings

While all three products could be amplified in fresh specimens and those fixed for 1 day, only the 420 bp fragment could be amplified in specimens fixed for 3 days, and no products were amplified in specimens fixed for 7 days. Further, the yield of the 420 bp product was reduced in specimens fixed for 3 days compared to those fixed for 1 day. Fixed specimens had 3-4 fold more mutations than fresh specimens (P<0.05), but the number of mutations identified was not affected by fixation duration or fragment size. 92% of the mutations identified in fixed specimens were transition mutations (A-G or C-T), and 6.6% were small deletions or additions of short repeats. Further, mutations were more likely to occur at AT pairs than GC pairs (2.9:1, versus 1.2:1, p=0.034). The mutations identified were scattered evenly throughout the gene fragments. The authors report that using AmpliTaq gold rather than AmpliTaq increased PCR yields but did not affect mutation rates.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    FormalinNone (Fresh)
  • Diagnoses

    Normal
    NeoplasticNormal Adjacent
  • Platforms

    DNAPCR
    DNADNA sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationTime in fixative
    1 day
    3 days
    7 days
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    None (fresh)
    PCR SpecificLength of gene fragment
    1007 bp
    420 bp
    589 bp
    PCR SpecificNucleic acid amplification
    AmpliTaq
    AmpliTaq gold
    PCR SpecificTargeted nucleic acid
    Mutation cluster region of the APC gene