Blood spot versus plasma chitotriosidase: A systematic clinical comparison.

Elmonem MA, Ramadan DI, Issac MS, Selim LA, Elkateb SM

Publication: Clin Biochem (2014) • Vol 47 • Page 38-43PMID: 24177195View on PubMed

Purpose

The purpose of this paper was to determine the effects of using dried blood spots (DBS) rather than plasma and storage on the measured chitotriosidase activity in specimens from children with confirmed lysosomal storage disorders, healthy controls and children with other pathological conditions.

Conclusion

The limit of detection and the coefficients of variance were similar for DBS and plasma, but the linearity limit of the chitotriosidase activity assay was considerably higher for plasma then DBS. Chitotriosidase levels in plasma declined within 2 days when stored at 37 degrees C, but levels were stable when plasma was stored for up to 30 days at room temperature and for at least 4 months at 4 or -80 degrees C. Chitotriosidase activity in DBS was stable for 10, 33 and 40 days at 37 degrees C, room temperature, and 4 degrees C, respectively, but then increased. Chitotriosidase activity in DBS was maintained during the 4 months of storage at -80 degrees C. The sensitivity and specificity for diagnosis of lysosomal storage disorders were 75.0 and 85.3%, respectively, for plasma and 71.4 and 79.0%, respectively, for DBS.

Studies (1)

Purpose

The purpose of this study was to determine the effects of using DBS rather than plasma and storage on the measured chitotriosidase activity in specimens from children with confirmed lysosomal storage disorders, healthy controls and children with other pathological conditions. The children with other pathological conditions had symptoms similar to those of lysosomal storage disorders but were diagnosed with other conditions. EDTA blood was spotted on Whatman paper, allowed to dry at room temperature and then frozen at -80 degrees C. Plasma was obtained from the same EDTA blood specimens and stored frozen at -80 degrees C. Blood spot specimens were coded and blinded prior to analysis.

Summary of Findings

The limit of detection was similar for plasma and DBS (2.7 and 2.0 nmol/mL/h, respectively), and the coefficients of variance were similar at 13.6 and 14.1%, respectively for the chitotriosidase activity assay; however the linearity limit of the assay was considerably higher for plasma then DBS (500 versus 150 nmol/mL/h). Chitotriosidase levels in plasma declined within 2 days when stored at 37 degrees C, but levels were stable for up to 30 days at room temperature and for at least 4 months at 4 or -80 degrees C. Chitotriosidase activity in DBS was stable for 10, 33 and 40 days at 37 degrees C, room temperature, and 4 degrees C, respectively, but then increased. Chitotriosidase activity was maintained in DBS during the 4 months of storage at -80 degrees C. The sensitivity and specificity for diagnosis of lysosomal storage disorders were 75.0 and 85.3%, respectively, for plasma and 71.4 and 79.0%, respectively, for DBS.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Other PreservativeFrozen
  • Diagnoses

    Other diagnoses
    Normal
  • Platforms

    ProteinEnzyme assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Lysosomal storage disorders
    Normal
    Other pathological conditions
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen
    StorageStorage duration
    0 days
    10 days
    14 days
    2 days
    21 days
    30 days
    4 days
    4 months
    40 days
    50 days
    7 days
    70 days
    85 days
    StorageStorage temperature
    -80 degrees C
    37 degrees C
    4 degrees C
    Room temperature