Interindividual variability of hemolysis in plasma samples during pneumatic tube system transport.
Gomez-Rioja R, Fernandez-Calle P, Alcaide MJ, Madero R, Oliver P, Iturzaeta JM, Buno A
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of PTS transport on levels of LDH, potassium, AST, and hemolysis index in lithium-heparin plasma specimens. All blood specimens were transported in carriers with foam lining and data loggers, with aliquots removed after each leg of the trip and all specimens centrifuged simultaneously. TSSAC was calculated from the data loggers included in the PTS carrier.
Summary of Findings
The TSSAC was strongly correlated with LDH (r=0.73) and modestly correlated with the hemolysis index (r=0.649), and levels of AST (r=0.56), and potassium (r=0.53); however, there was considerable interindividual variability in the susceptibility to TSSAC. Further, clinically significant changes in LD were first identified with a TSSAC of 0.69 g x 10^3 which corresponded to a single PTS trip in the tested system. The safe threshold for the remaining analytes allowed for multiple PTS trips in the system under study, but due to interindividual variability in susceptibility and differences between PTS in different locations, the authors urge caution.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerCell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Specimen transport duration/condition Transported four timesTransported onceTransported three timesTransported twiceStorage Within hospital transportation method Hand-deliveredPneumatic tube system