Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory.
Dastych M, Cermáková Z
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of PTS transport and tube type on levels of potassium in plasma and serum from patients with CLL, CML and ALL. Blood was collected into 1 heparinized syringe, 2 Li-heparin tubes without separator, 2 Li-heparin tubes with separator gel, and 2 serum tubes with separator gel. Blood in the heparinized syringe was analyzed at bedside using a GEM Premier 4000 analyzer, while one of each of the remaining tubes was transported by PTS and the other was hand-delivered to the laboratory where they were analyzed using a Cobas 701 Roche analyzer.
Summary of Findings
Hand delivering blood in lithium heparin or serum tubes to the lab rather than analyzing blood in heparinized syringes at bedside on a different analyzer had no effect on potassium levels in blood from patients with CLL. However, PTS transport of blood from patients with CLL led to elevated potassium when blood was in lithium heparin tubes, with or without separator gel, compared to manually transported specimens. Further, for the single patient with CML and the single patient with ALL, PTS transport of blood in lithium heparin tubes (with or without separator) or serum tubes led to an increase in measured potassium levels compared to manually transported specimens.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
NeoplasticLeukemiaPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Acute lymphocytic leukemiaChronic lymphocytic leukemiaChronic myeloid leukemiaBiospecimen Acquisition Type of collection container/solution Heparinized syringeLi-heparin tube with gel separatorLi-heparin tube without separatorSerum tube with separator gelStorage Within hospital transportation method Hand-deliveredNot transportedPneumatic tube systemClinical chemistry/auto analyzer Specific Technology platform Cobas 701 Roche analyzerGEM Premier 4000 analyzer