Skip to main content

High-quality genotyping data from formalin-fixed, paraffin-embedded tissue on the drug metabolizing enzymes and transporters plus array.

Vos HI, van der Straaten T, Coenen MJ, Flucke U, te Loo DM, Guchelaar HJ

Publication: J Mol Diagn (2015) • Vol 17 • Page 4-9PMID: 25528187View on PubMed

Purpose

The purpose of this paper was to determine if the Affymetrix Drug Metabolizing Enzymes and Transporters (DMET) Plus array is suitable for genotyping analysis of formalin-fixed paraffin-embedded (FFPE) tissue specimens by comparing data with matched blood or saliva specimens.

Conclusion

Maximum amplicon sizes were smaller for FFPE specimens than from blood specimens. The mean genotyping call rates were only slightly lower for FFPE specimens than blood/saliva specimens. For all 1931 markers, the genotyping concordance between matched FFPE and blood/saliva specimens was 97.4% with all specimens except 1 having concordance of >98.5%. Genotype concordance increased when 2 specimen pairs were excluded due to low call rates, when rare alleles were excluded, or when 4 additional markers were excluded based on cluster plots. Most discordance between specimen pairs was attributed to no calls or rare allele calls using FFPE specimens, but homozygous/heterozygous calls were also a common source of discordance. 13 of the 1931 markers had significant differences in allele frequency between FFPE and blood/saliva specimens, but the authors state 9 of these had unreliable clustering. Importantly, discrepant calls resulted in discrepant haplotype and phenotype results for 7 genes between FFPE and blood/saliva specimens. The genotypes of 13 SNPs were confirmed using Illumina BeadArrays of blood or saliva specimens.

Studies (1)

Purpose

The purpose of this study was to compare Affymetrix DMET genotyping data obtained using FFPE specimens to that obtained using saliva or blood from patients with osteosarcoma. 16 FFPE blocks and matched blood (13) or saliva (3) specimens from patients with osteosarcoma were stored for 3-19 years. DNA was extracted from sections containing normal lung, muscle, lymph node, and/or skin using a modification of the QIAamp DNA Micro Kit, from blood using the QIAamp DNA Blood Midi kit and from saliva using the Oragene DNA kit. Blood and saliva are assumed to have been stored frozen, but conditions of archival storage were not described. Fluids were compared with tissues as a group, but saliva was not compared with blood and tissue types were not compared with each other.

Summary of Findings

While all 4 PCR products (100-400 bp) were amplifiable from blood specimens, the 400 bp product was not amplifiable from FFPE specimens and the 300 bp and 200 bp products were only amplifiable from 2/16 and 10/16 FFPE specimens, respectively. The mean genotyping call rates were 99.4% ± 0.30% for blood/saliva DNA and 98.9% ± 1.0% for FFPE specimens. Importantly, 14/16 FFPE specimens yielded call rates >98%, and the 2 specimens with lower call rates also only allowed for amplification of the 100 bp fragment. For all 1931 markers, the genotyping concordance between matched FFPE and blood/saliva specimens was 97.4%, but when no calls were excluded, the concordance for pairs ranged from 97.46-99.48% with all specimens except 1 having concordance of >98.5%. When rare alleles were excluded, genotype concordance increased slightly for all 16 specimens (98.42-99.89%), and exclusion of 4 markers based on cluster plots further increased concordance. 81.1% of discordant calls were due to no calls or rare allele calls using FFPE specimens. 11.01% of discordant calls were due to a homozygous call using blood or saliva and a heterozygous call using FFPE, and 6.2% of discordant calls were due to the reverse. Only 1.13% and 0.5% of discordant calls were due to full switches (homozygous one allele to homozygous another) and allele deletions, respectively. 13 of the 1931 markers had significant differences in allele frequency between FFPE and blood/saliva specimens, but the authors state 9 of these had unreliable clustering. Importantly, discrepant calls resulted in discrepant haplotype and phenotype results for 7 genes between FFPE and blood/saliva specimens. The genotypes of 13 SNPs were confirmed using Illumina BeadArrays of blood or saliva specimens.

  • Biospecimens

    FluidBlood
    FluidSaliva
    TissueLung
    TissueMuscle (Skeletal)
    TissueSkin
    TissueLymph Node
  • Preservation Types

    FormalinFrozen
  • Diagnoses

    NeoplasticSarcoma
  • Platforms

    DNAPCR
    DNADNA microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Blood
    Lung
    Lymph
    Muscle
    Saliva
    Skin
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen
    PCR SpecificLength of gene fragment
    100 bp
    200 bp
    300 bp
    400 bp
    DNA microarray SpecificTechnology platform
    Affymetrix DMET Plus array
    Illumina BeadArray