The purpose of this paper was to determine the effects of long-term storage in liquid nitrogen vapor and short-term storage at -80°C on umbilical cord blood (UCB) quality and viability.
Postthaw characterization of umbilical cord blood: markers of storage lesion.
Hubel A, Spindler R, Curtsinger JM, Lindgren B, Wiederoder S, McKenna DH
Purpose
Conclusion
When UCB was stored in liquid nitrogen for >11 years instead of 1 year, the CD34 positive fraction and percentage of viable cells increased, and the fraction of early apoptotic cells decreased, but the number of colony forming units (CFU), total nucleated cells (TNCs), necrotic cells, and late apoptotic cells were not significantly different. When UCB was transferred to -80°C for storage, CFUs, viable cells and CD34+ cell fractions declined progressively with longer storage, and the percentage of cells displaying markers for early or late apoptosis increased.
Studies (2)
Purpose
The purpose of this study was to determine the effects of storing UCB in liquid nitrogen vapor for >11 years rather than 1 year on UCB quality. UCB was red blood cell (RBC)-reduced, cryopreserved with DMSO, frozen in a controlled rate freezer and stored in liquid nitrogen vapor for 1 year (16 specimens) or >11 years (17-21 specimens). UCB was thawed in a 37°C water bath.
Summary of Findings
When UCB was stored in liquid nitrogen for >11 years instead of 1 year, the CD34 positive fraction increased (p=0.049), the fraction of early apoptotic cells decreased (p=0.006) and the percentage of viable cells increased (p=0.038), but the number of CFUs, TNCs, necrotic cells, and late apoptotic cells were not significantly different.
Biospecimens
FluidCord BloodCellCord BloodPreservation Types
FrozenDiagnoses
PregnantPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeMacroscopic observationCell count/volumeFlow cytometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 1 year11.5-16.1 years
Purpose
The purpose of this study was to determine the effects of storage at -80°C on UCB quality. 34-38 UCB specimens were RBC-reduced, cryopreserved with DMSO, frozen in a controlled rate freezer, stored in liquid nitrogen vapor and then transferred to -80°C for 1 week, 1 month, 3 months or 6 months before thawing in a 37°C water bath.
Summary of Findings
When UCB was transferred to -80°C for storage, CFUs, viable cells and CD34+ cell fractions declined progressively with longer storage. Further, the percentages of cells displaying markers for early or late apoptosis increased by 0.114% (p=0.003) and 5.537% (p<0.001) per month, respectively.
Biospecimens
CellCord BloodFluidCord BloodPreservation Types
FrozenDiagnoses
PregnantPlatforms
Cell count/volumeFlow cytometryCell count/volumeHematology/ auto analyzerCell count/volumeMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 weeks1 month1 week3 months6 monthsStorage Storage temperature -150°C (liquid nitrogen vapor)-80°C