Changes in coagulation factor activity and content of di(2-ethylhexyl)phthalate in frozen plasma units during refrigerated storage for up to five days after thawing.
Sheffield WP, Bhakta V, Mastronardi C, Ramirez-Arcos S, Howe D, Jenkins C
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of refrigerated storage of thawed plasma for up to 5 days on clotting factor activity and DEHP. Plasma was obtained by the buffy-coat method within 24 h of collection of blood anticoagulated with citrate-phosphate-dextrose (CPD). Plasma was stored frozen for 1-6 months, shipped on dry ice, and stored at -80 degrees C until thawing. Plasma was thawed in a 37 degrees C water bath for 20 min and stored at 1-6 degrees C. Plasma aliquots for DEHP analysis were refrozen, stored for 1 month at -80 degrees C and shipped internationally (Canada to Netherlands) prior to DEHP quantification.
Summary of Findings
Compared to levels measured immediately after thawing, plasma refrigerated for 1 day had significantly lower FV (8%, p<0.05) and FVIII (27%, p<0.05) activity and a significantly longer PT (p<0.05). After 5 days of post-thaw refrigerated storage, the activity of FVII was 14% lower than the activity measured immediately after thawing (p<0.05), but fibrinogen activity remained unchanged. The authors report that bag type had an effect on fibrinogen activity but not on FV, FVII, or FVIII activity or PT. DEHP levels were higher in plasma stored in MacoPharma bags than Fenwal bags (p<0.05, at all timepoints) and increased with longer post-thaw refrigerated storage in MacoPharma bags (p<0.05) but not Fenwal bags.
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinHematology/ auto analyzerSmall moleculeHPLCMorphologyHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 h1 day3 days5 daysStorage Type of storage container Fenwal bagsMacoPharma bags