Down syndrome and cell-free fetal DNA in archived maternal serum.

Lee T, LeShane ES, Messerlian GM, Canick JA, Farina A, Heber WW, Bianchi DW

Publication: Am J Obstet Gynecol (2002) • Vol 187 • Page 1217-21PMID: 12439507View on PubMed

Purpose

The purpose of this paper was to determine the effects of fetal down syndrome and frozen storage duration on fetal DNA levels in serum and amniotic fluid from pregnant women.

Conclusion

Fetal DNA concentrations increased with gestational age and were higher in serum, but not amniotic fluid, from women carrying fetuses with down syndrome than specimens from women carrying euploid fetuses. There was a non-significant trend toward decreased fetal DNA with increased storage of serum, but the same was not true for storage of amniotic fluid.

Studies (1)

Purpose

The purpose of this study was to determine the effects of fetal down syndrome and frozen storage duration on fetal DNA levels in serum and amniotic fluid from pregnant women. 11 frozen serum and 6 frozen amniotic fluid specimens from women carrying male fetuses with down syndrome (47, XY, +21 ) were compared with 55 frozen serum and 30 amniotic fluid specimens from women carrying normal (euploid) male fetuses at the same gestational ages and matched for storage duration at -20°C. Specimens were thawed at 37°C, and fetal DNA was quantified by real-time PCR amplification of the DYS1 locus. Storage effects were investigated using only the 55 serum and 30 amniotic fluid specimens from women carrying euploid fetuses.

Summary of Findings

Fetal DNA concentrations increased with gestational age. Rank sum analysis showed a higher than expected serum fetal DNA level when the patient was carrying a fetus with down syndrome (p<0.005) versus a normal fetus. Further, serum from women carrying fetuses with down syndrome had 1.7 fold more fetal DNA than serum from women carrying euploid fetuses (p=0.002). Fetal DNA levels in amniotic fluid were comparable in women carrying down syndrome and euploid fetuses. A non-significant decrease of 0.66 genome equivalents (GE) fetal DNA/month of serum storage was observed, but no similar trend was observed after storage of amniotic fluid.

  • Biospecimens

    FluidSerum
    FluidAmniotic Fluid
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Pregnant
    Down Syndrome
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Pregnant with Down syndrome fetus
    Pregnant with euploid fetus
    PreaquisitionPatient age
    15-19 weeks gestation
    PreaquisitionPatient genotype
    46, XY
    47, XY, +21
    StorageStorage duration
    16-36 months