Skip to main content

Does centrifugation cause the ex vivo release of DNA from blood cells?

Lui YY, Chik KW, Lo YM

Publication: Clin Chem (2002) • Vol 48 • Page 2074-6PMID: 12407004View on PubMed

Purpose

The purpose of this paper was to determine the effect of centrifugation speed on the cell-free DNA concentration in plasma.

Conclusion

The amount of DNA obtained from plasma was not affected by the centrifugation speed used for plasma separation among specimens from healthy individuals and bone marrow transplant patients.

Studies (1)

Purpose

The purpose of this study was to determine the effect of centrifugation speed on the cell-free DNA concentration in plasma. Peripheral blood was collected from 6 bone marrow transplant and 10 healthy patients into EDTA tubes and centrifuged for 10 min at 400, 800, 1500, 3000, or 16000 x g. Plasma was then filtered to remove cells. DNA was extracted from plasma using the QIAamp blood kit. DNA was quantified by amplification of the beta-globin gene.

Summary of Findings

The amount of DNA obtained from plasma was not affected by the centrifugation speed used for plasma separation among specimens from healthy individuals and bone marrow transplant patients.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Bone marrow transplant patient
    Healthy
    Biospecimen Aliquots and ComponentsCentrifugation
    Multiple speeds compared
    Real-time qPCR SpecificTargeted nucleic acid
    Beta-globin