The purpose of this paper was to determine the effect of centrifugation speed on the cell-free DNA concentration in plasma.
Does centrifugation cause the ex vivo release of DNA from blood cells?
Lui YY, Chik KW, Lo YM
Purpose
Conclusion
The amount of DNA obtained from plasma was not affected by the centrifugation speed used for plasma separation among specimens from healthy individuals and bone marrow transplant patients.
Studies (1)
Purpose
The purpose of this study was to determine the effect of centrifugation speed on the cell-free DNA concentration in plasma. Peripheral blood was collected from 6 bone marrow transplant and 10 healthy patients into EDTA tubes and centrifuged for 10 min at 400, 800, 1500, 3000, or 16000 x g. Plasma was then filtered to remove cells. DNA was extracted from plasma using the QIAamp blood kit. DNA was quantified by amplification of the beta-globin gene.
Summary of Findings
The amount of DNA obtained from plasma was not affected by the centrifugation speed used for plasma separation among specimens from healthy individuals and bone marrow transplant patients.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalOther diagnosesPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Bone marrow transplant patientHealthyBiospecimen Aliquots and Components Centrifugation Multiple speeds comparedReal-time qPCR Specific Targeted nucleic acid Beta-globin