Skip to main content

Next-generation sequencing of RNA and DNA isolated from paired fresh-frozen and formalin-fixed paraffin-embedded samples of human cancer and normal tissue.

Hedegaard J, Thorsen K, Lund MK, Hein AM, Hamilton-Dutoit SJ, Vang S, Nordentoft I, Birkenkamp-Demtröder K, Kruhøffer M, Hager H, Knudsen B, Andersen CL, Sørensen KD, Pedersen JS, Ørntoft TF, Dyrskjøt L

Publication: PLoS One (2014) • Vol 9 • Page e98187PMID: 24878701View on PubMed

Purpose

The purpose of this paper was to determine the effects of formalin fixation, extraction method, storage duration, tissue type, and tumor status on DNA and RNA next generation sequencing (NGS) results using formalin-fixed, paraffin-embedded (FFPE) and frozen specimens.

Conclusion

RNA and DNA yields from FFPE specimens were dependent on the extraction method, and RNA and DNA integrity were adversely affected by FFPE block storage. NGS library construction from FFPE specimens resulted in more duplication and a high failure rate for DNA but not RNA. FFPE DNA generated a lower percentage of mapped reads, more unaligned ends, more non-perfectly aligned reads, and more transition errors (T<->C and A<->G) than matched frozen specimens, and these differences increased with block storage. For FFPE RNA, a higher percentage of non-perfect matches and a lower percentage of total exon mapping were observed than with the frozen specimens, but the percentage of non-mapped reads was comparable. While the expression data between matched FFPE and frozen specimens was strongly correlated, 1494 genes were found to be differentially expressed between frozen and FFPE specimens in all three tissue types. Some of these genes overlapped with genes that were differentially expressed between normal adjacent and tumor specimens, but the specimens still clustered based on diagnosis.

Studies (4)

Purpose

The purpose of this study was to determine the effect of storage duration and extraction kit on the yield and integrity of DNA and RNA from FFPE specimens. The effect of extraction kit was tested using 16 specimens including normal liver and skin, reactive tonsil and liver, lung, breast and bladder carcinomas.

Summary of Findings

RNA yield and integrity were highest when extraction was performed using the miRNeasy FFPE or ExpressArt kits rather than the Nucleospin kit, and DNA yields were highest using the QIAamp FFPE DNA kit rather than the Nucleospin kit. Co-purification of RNA and DNA using either QIAsymphony or RecoverAll resulted in low DNA and RNA yields. RNA and DNA integrity were adversely affected by FFPE block storage duration, but RNA fragments of up to 4000 bp could still be isolated from blocks stored for up to 13 months.

  • Biospecimens

    TissueBladder
    TissueTonsil
    TissueLiver
    TissueSkin
    TissueBreast
    TissueLung
  • Preservation Types

    FrozenFormalin
  • Diagnoses

    NeoplasticCarcinoma
    Other diagnoses
    Normal
  • Platforms

    DNAFluorometry
    DNASpectrophotometry
    RNAAutomated electrophoresis/Bioanalyzer
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    13 months
    2 months
    241 months
    63 months
    Analyte Extraction and PurificationAnalyte isolation method
    ExpressArt FFPE RNA ready
    Nucleospin FFPE DNA kit
    Nucleospin FFPE RNA
    QIAamp DNA FFPE Tissue
    QIAsymphony DSP DNA mini kit
    Qiasymphony DSP RNA kit
    RecoverAll Total Nucleic Acid Isolation Kit for FFPE
    miRNeasy FFPE