The purpose of this paper was to determine the effects of blood transport time and DNA extraction method on the detection of fetal blood factor Rh D (RhD) DNA in maternal plasma.
Cell-free fetal DNA in specimen from pregnant women is stable up to 5 days.
Müller SP, Bartels I, Stein W, Emons G, Gutensohn K, Legler TJ
Purpose
Conclusion
Significantly higher RhD cycle threshold (CT) values and total DNA yields were observed with increased blood transport time prior to centrifugation and isolation of plasma. Overall, there was no effect of blood transport time on the false positive rate for RhD status, but the false negative rate was affected by blood transport time. Specifically, there was a systematic increase in false negatives for RhD with increased transport time only when DNA was extracted by the manual method.
Studies (1)
Purpose
The purpose of this study was to determine the effects of blood transport time and DNA extraction method on the detection of fetal RhD DNA in maternal plasma. EDTA anticoagulated blood from 972 RhD negative pregnant women (6-32 weeks pregnant) was shipped at room temperature within Germany, and plasma was isolated upon arrival. Any delay in processing of the blood to plasma and freezing at -80°C was included in transport time. DNA was extracted from plasma using the manual QIAamp DSP virus kit and the automated Chemagic magnetic separation module. RhD status was compared with status determined post-natally using cord blood.
Summary of Findings
DNA yield increased significantly with increased transport duration (p<0.01). Transport time also significantly impacted the RhD cycle threshold (CT) values for DNA obtained by either DNA extraction method (p=0.00013 for automated and p<0.00001 for manual). While significantly higher CT values were observed when transport time was ≥6 days rather than <6 days for both extraction methods(p=0.0292 for manual extraction and 0.0232 for automated extraction), the difference in CT value between specimens with a <2 day rather than ≥2 day transport time was only significant when DNA was extracted by the manual method (p=0.000003), and the difference in CT value between specimens with a <3 day rather than ≥3 day transport time was only significant when DNA was extracted by the automated method (p=0.0099). While there was no effect of transport time on the false positive rate for RhD status for DNA extracted by either method (p=0.198 for manual and p=0.265 for automated), the false negative rate was affected by transport time when DNA was extracted by either method (p=0.0013 for manual and p=0.0099 for automated). False negatives for RhD status were found more often when the transport time was ≥2 days than when <2 days when DNA was extracted by the manual method (p<0.0001).
Biospecimens
FluidBloodFluidPlasmaPreservation Types
FrozenDiagnoses
PregnantPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location Cord bloodMaternal bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Between site transportation method MailedStorage Specimen transport duration/condition 0 days1 days2 days3 days4 days5 days6 days7 days8 daysAnalyte Extraction and Purification Analyte isolation method Chemagic magnetic separation module (Automated)QIAamp DSP virus kit (Manual)Real-time qPCR Specific Targeted nucleic acid RhD