Skip to main content

Genome-wide comparison of two RNA-stabilizing reagents for transcriptional profiling of peripheral blood.

Nikula T, Mykkänen J, Simell O, Lahesmaa R

Publication: Transl Res (2013) • Vol 161 • Page 181-8PMID: 23138105View on PubMed

Purpose

The purpose of this paper was to determine the effects of using the PAXgene or TEMPUS blood preservation systems, globin reduction, and pre-amplification on RNA yield, quality and transcriptional profiles by Illumina BeadChip Arrays.

Conclusion

While high quality RNA was obtained when either blood preservation system was used, less RNA was obtained from PAXgene blood than TEMPUS blood. Globin reduction led to reduced RNA quality, but amplification with RiboAmp did not amplify globin, resulting in reduction of globin compared to other transcripts without RNA degradation. A total of 5200 genes were detected by Illumina BeadChip Array, and 3,058 of these genes were detected in PAXgene, TEMPUS, and frozen blood specimens. The gene expression profile of peripheral blood mononuclear cells (PBMC) was closest to that of blood collected in TEMPUS tubes rather than blood collected in PAXgene tubes. The Pearson correlations for TEMPUS and PAXgene specimens drawn simultaneously were very strong. A total of 443 genes were differentially expressed between PAXgene and TEMPUS specimens, of which 94% were expressed at higher levels in the TEMPUS specimen than the PAXgene specimen. No particular pathways were identified as being affected by the type of preservation system using Gene Set Enrichment Analysis (GSEA), however, ingenuity pathways analysis identified 9 pathways differentially affected by PAXgene and TEMPUS preservation. The differentially expressed genes were enzymes, kinases or transcriptional regulators.

Studies (1)

Purpose

The purpose of this study was to determine the effects of using the PAXgene or TEMPUS blood preservation systems, globin reduction, and pre-amplification on RNA yield, quality and transcriptional profiles by Illumina BeadChip Arrays. Blood was processed according to the manufacturers' instructions for each preservation tube type and stored at -70 degrees C. RNA was isolated from PAXgene blood using PAXgene tubes and from TEMPUS blood using the ABI Prism Nucleic Acid PrepStation kit. To investigate the effects of amplification some RNA specimens were amplified with the RiboAmp kit prior to labeling and additional amplification with the Illumina RNA Amplification Kit.

Summary of Findings

While high quality RNA was obtained when either blood preservation system was used, less RNA was obtained from PAXgene blood than TEMPUS blood (1.0 ug/mL blood versus 1.83 ug/mL blood). Globin reduction led to reduced RNA quality, but amplification with RiboAmp did not amplify globin, resulting in reduction of globin compared to other transcripts without RNA degradation. A total of 5200 genes were detected by Illumina BeadChip Array, and 3,058 of these genes were detected in PAXgene, TEMPUS, and frozen blood specimens. The gene expression profile of PBMC was closest to that of blood collected in TEMPUS tubes (r=0.83) rather than blood collected in PAXgene tubes (r=0.75). The Pearson correlations for TEMPUS and PAXgene specimens drawn simultaneously were very strong (r ≥0.94). A total of 443 genes were differentially expressed between PAXgene and TEMPUS specimens, of which 94% were expressed at higher levels in the TEMPUS specimen than the PAXgene specimen. No particular pathways were identified as being affected by the type of preservation system using GSEA, however, ingenuity pathways analysis identified 9 pathways differentially affected by PAXgene and TEMPUS preservation. The differentially expressed genes were enzymes, kinases or transcriptional regulators.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other PreservativePAXgene
  • Diagnoses

    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNADNA microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    PAXgene tube
    TEMPUS tube
    Biospecimen PreservationType of fixation/preservation
    Frozen
    PAXgene
    Tempus
    Analyte Extraction and PurificationAnalyte isolation method
    ABI Prism Nucleic Acid PrepStation
    PAXgene spin columns
    DNA microarray SpecificData handling
    GSEA
    Ingenuity pathways analysis
    DNA microarray SpecificNucleic acid amplification
    Preamplified with RiboAmp
    DNA microarray SpecificTemplate modification
    Globin-reduced
    None