Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots.

Kuwahata M, Wijesinghe R, Ho MF, Pelecanos A, Bobogare A, Landry L, Bugora H, Vallely A, McCarthy J

Publication: Malar J (2010) • Vol 9 • Page 223PMID: 20684792View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage of dried blood spots (DBS), fresh blood assay type, and patient gender on measured levels of glucose-6-phosphate dehydrogenase (G6PD).

Conclusion

Regardless of storage temperature, after 1 day of storage of DBS, G6PD levels were comparable to initial levels, however, declines were noted in DBS stored at room temperature or 37 degrees C for 5 days or 4 degrees C for 10 days. All three kits correctly diagnosed 14 individuals with G6PD levels in the normal range and 5 with deficiencies using liquid blood specimens, but 1 specimen was determined to have intermediate levels by the quantitative Trinity Biotech assay and the WST8 assay and was classified as deficient by RDT assay. While moderate G6PD deficiency was observed in a similar percentage of males and females, severe deficiency was more prevalent in males than females.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage of DBS, fresh blood assay type, and patient gender on measured levels of G6PD. To examine the effects of storage temperature and duration, commercial G6PD was added to blood at known levels before spotting. The spots were air-dried and stored in Zip-Lock bags with desiccant. To compare three G6PD assays, liquid EDTA blood was tested within 4 days of collection. For the gender comparison, finger-prick blood from 8541 people from the Solomon Islands was spotted on 3 MM Whatman paper and air-dried at ambient temperature. Once dried, blood spots were stored in Zip-Lock bags with desiccant at ambient temperatures.

Summary of Findings

Regardless of storage temperature, after 1 day of storage of DBS, G6PD levels were comparable to initial levels, however, after 5 days of storage at room temperature or 37 degrees C or 10 days at 4 degrees C, G6PD levels had decreased by 5% of initial levels. The reagents used for assay could be stored for 2 weeks at ambient temperature without adverse effects on measurements. All three kits correctly diagnosed 14 individuals with G6PD levels in the normal range and 5 with deficiencies using liquid blood specimens. However, 1 specimen was determined to contain intermediate levels by the quantitative Trinity Biotech assay and by the WST8 assay, but was categorized as G6PD deficient by RDT assay. While moderate G6PD deficiency (<15% normal levels) was observed in 21.7% of males (843 of 3,880) and 19.1% of females (886 of 4,636), severe deficiency (<10% of normal levels) was more prevalent in males than females (10.9% versus 3.6%, p<0.0001).

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinEnzyme assay
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    None (fresh)
    StorageStorage duration
    1 day
    10 days
    14 days
    5 days
    StorageStorage temperature
    37 degrees C
    4 degrees C
    Room temperature
    Clinical chemistry/auto analyzer SpecificTechnology platform
    RDT-Binax Now
    Trinity Biotech assay
    WST8 assay