The impact of whole blood processing and freezing conditions on the quality of therapeutic plasma prepared from whole blood.

Runkel S, Hitzler WE, Hellstern P

Publication: Transfusion (2015) • Vol 55 • Page 796-804PMID: 25371048View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed centrifugation, storage duration and storage and freezing temperature on coagulation parameters in plasma.

Conclusion

Storage of plasma at room temperature before freezing resulted in significant effects on Factor (F)VIII, Protein S (PS), and activated partial thromboplastin time (APTT), and when plasma was stored at 4°C, significant effects on FVII, FVIII, prothrombin time (PT) and APTT were observed. Freezing at -30°C rather than at -20°C resulted in higher levels of FVII, FVIII, and FXI, shorter PT and APTT and higher PS activity, but the significance depended on storage duration and temperature, with the largest effects observed in specimens frozen immediately (<8 h after blood collection) and the smallest effects observed when plasma was stored at room temperature or 4 degrees C until 24 h after blood collection. Storage of whole blood rather than plasma for 24 h at room temperature before freezing at -20°C resulted in lower FVII levels, longer PT and higher PS activity in plasma.

Studies (2)

Purpose

The purpose of this study was to determine the effects of plasma storage duration and temperature and freezing temperature on coagulation parameters in plasma. Blood was collected from 6 men and 90 women, cooled to room temperature within 1 h, and leukoreduced before centrifugation to obtain plasma within 8 h of collection. Plasma was pooled to create 16 pools which were spilt to test each condition. Plasma was then frozen immediately at -20°C (slow) or -30°C within 1 h (rapid), or stored for an additional ~16 h at room temperature or 4°C until freezing at -20°C or -30°C (24 h post collection).  Freezing at -20°C took up to 730 min, while freezing at -30°C took <1 h. Plasma was thawed at 37°C and tested within 2 h (FVIII and Protein S) or 4 h (all other analytes).

Summary of Findings

For specimens frozen at -20°C, storage of plasma at 4°C for ~16 h resulted in lower FVIII levels (p<0.0001) and longer APTT and PT (p<0.0001 and p=0.008, respectively) and storage at room temperature for ~16 h resulted in decreased FVIII levels (p=0.002), and PS activity (p<0.0001) and longer APTT (p<0.0001) than when specimens were frozen immediately following plasma isolation. Similarly, when specimens were frozen at -30°C, storage of plasma at 4°C for ~16 h resulted in decreased FVII and FVIII levels (p=0.0001 and p<0.0001, respectively), and longer PT and APTT (p=0.002 and p<0.0001, respectively), and storage at room temperature for ~16 h resulted in decreased FVIII levels (p<0.0001) and PS activity (p<0.0001) and longer APTT (p=0.006) compared to specimens frozen immediately following the centrifugation. Freezing plasma at -30°C rather than at -20°C resulted in higher levels of FVII, FVIII, and FXI, shorter PT and APTT and higher PS activity, but the significance depended on prior storage with the largest effects observed in specimens frozen immediately following plasma separation and the smallest effects observed when plasma was stored at room temperature or 4°C prior to freezing. Compared to plasma frozen at -30°C after isolation (<8 h post-collection), plasma stored at room temperature until 24 h post blood collection and then frozen at -20°C had lower levels of FV (p=0.02), FVII (p=0.001), FVIII (p=0.0001), FXI (p=0.009), and free PS (p=0.001) longer PT (p<0.0001) and APTT (p<0.0001), and lower PS activity (p<0.0001). von Willebrand factor, ristocetin cofactor activity, fibrinogen and protein C were unaffected by delayed centrifugation, plasma storage and freezing rate.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    MorphologyHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    ProteinColorimetric assay
    ProteinImmunoassay
    GlycoproteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationCooling or freezing method/ rate
    At -20 degrees C
    At -30 degrees C
    StorageStorage duration
    1 h
    16 h
    StorageStorage temperature
    -20°C
    -30°C
    4°C