Comparison of arterial versus venous parameters of Rotational thromboelastometry and multiple platelet function analyzer: results of a pilot study.

Oswald E, Finsterwalder T, Innerhofer N, Haas T, Mittermayr M, Strohmaier S, Innerhofer P

Publication: Scand J Clin Lab Invest (2013) • Vol 73 • Page 538-45PMID: 24007593View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection time with respect to surgery and using arterial versus venous blood on results of rotational thromboelastometry (ROTEM) and Multiplate clotting and impedance aggregometry assays with specimens from patients undergoing orthopedic surgery.

Conclusion

A few specific significant differences were noted between arterial and venous measurements for ROTEM and Multiplate assays at individual time points and between arterial measurements taken at different time points relative to surgery. Importantly, none of the differences between arterial and venous measurements were clinically significant, except the Multiplate TRAP assay results at T0, where significantly more pathological results were obtained with the venous blood specimens than the arterial specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection time with respect to surgery and using arterial versus venous blood on the results of ROTEM and Multiplate clotting and impedance aggregometry assays with specimens from patients undergoing orthopedic surgery. Arterial and venous blood specimens were obtained through arterial and central venous catheters, respectively, simultaneously in citrated tubes for ROTEM analysis and hirudin tubes for Multiplate analysis. ROTEM assays were performed at bedside within 10 minutes of specimen collection, while Multiplate assays were performed after blood was held at room temperature for 30 min per manufacturer's recommendation.

Summary of Findings

While the authors did not present statistical significance, at the end of surgery (T2), hemoglobin, platelet counts, and fibrinogen levels were lower, and activated partial thromboplastin time (aPTT) was longer compared to preoperative measurements (T0). The authors state that arterial and venous measurements for all ROTEM and Multiplate assays correlated significantly at T0, T1, and T2. However, a few specific significant differences were noted between arterial and venous measurements at individual time points and between arterial measurements taken at different time points relative to surgery. Importantly, none of the differences between arterial and venous measurements were clinically significant, except the Multiplate TRAP assay results at T0 where significantly more pathological results were obtained with the venous blood specimen than the arterial specimen (p=0.0455).

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
    GlycoproteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Undergoing major elective orthopedic surgery
    Biospecimen AcquisitionAnatomical location of blood draw
    Artery
    Vein
    Biospecimen AcquisitionTime of biospecimen collection
    At the end of surgery (T2)
    Intraoperatively (T1)
    Pre-surgery (T0)
    Hematology/ auto analyzer SpecificReaction solution
    ADP
    ASPI
    EXTEM
    FIBTEM
    INTEM
    TRAP
    Hematology/ auto analyzer SpecificTechnology platform
    Multiplate
    ROTEM