Skip to main content

Characterization of differences between blood sample matrices in untargeted metabolomics.

Denery JR, Nunes AA, Dickerson TJ

Publication: Anal Chem (2011) • Vol 83 • Page 1040-7PMID: 21175165View on PubMed

Purpose

The purpose of this paper was to determine the effects of type of anticoagulant, clotting time, capillary versus venous blood collection, and analysis of serum versus plasma on the metabolomic profile of blood specimens.

Conclusion

Neither the type of anticoagulant used for plasma specimens nor a 30 min-4 h delay before centrifugation for serum specimens influenced the average number of features identified by electrospray ionization time-of-flight mass spectrometry (ESI-TOF MS). When either the positive or negative ionization modes were used, a majority of identified compounds were found to overlap between plasma and serum specimens and between venous and capillary specimens. Although, overall, more compounds were identified in serum and capillary specimens, respectively. The authors were able to identify several differentially expressed compounds of interest for each of the two comparisons (plasma versus serum and venous versus capillary collection).

Studies (1)

Purpose

The purpose of this study was to determine the effects of type of anticoagulant, clotting time, capillary versus venous collection, and analysis of serum versus plasma on the metabolomic profile of blood specimens. In all cases, capillary blood was obtained prior to venipuncture. After collections for the capillary and venous serum comparisons, tubes were allowed to clot, placed on ice for 3-4 h, and centrifuged. For the comparison of plasma with serum, venous blood was collected into heparin or plain tubes, left at room temperature for 30 min, placed on ice for 20 min, carefully aliquoted (without disturbing the clot for serum specimens), and centrifuged. All serum and plasma specimens were aliquoted, flash-frozen, and stored at -80 degrees C until analysis.

Summary of Findings

The average number of features identified in plasma specimens using different anticoagulants was not significantly different, and the authors used heparin for the rest of their analysis. There were also no significant differences between the average number of features identified in serum from blood allowed to clot for 30 min or 4 h before centrifugation. When either the positive or negative ionization modes were used during ESI-TOF-MS analysis, a majority of identified compounds were found to overlap between plasma and serum specimens, but more compounds were identified in serum. With the positive ionization mode, 44 compounds fit the criteria of being identified in 100% of specimens and having a >2-fold change between serum and plasma which was significant (p<0.05). With the negative ionization mode, only 3 compounds fit the criteria. As for the comparison between capillary and venous serum, again, a majority of identified compounds were found to overlap between the two specimen types, and overall, more compounds were identified in capillary specimens. With the application of further restrictive criteria (present in 66% of specimens, >2-fold change, p<0.05), 14 molecules of interest were identified in the positive ionization mode and 9 in the negative ionization mode with differential expression between capillary and venous serum. Importantly, several poly-ethylene glycol polymers fit the restrictive criteria which, the authors hypothesized, were the result of exogenous contamination from skin preparation with alcohol wipes prior to blood collection and were eliminated before the final 14 and 9 of interest were identified. Interestingly, through MS/MS analysis, the authors determined that most of these features of interest in the capillary specimens have the same mass and fragmentation patterns as surfactants, antimicrobials, detergents, and stabilizers.

  • Biospecimens

    FluidSerum
    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    Small moleculeESI MS
    PeptideESI MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Heparin
    Sodium citrate
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    30 min
    4 h
    ESI MS SpecificTechnology platform
    Negative ionization mode
    Positive ionization mode