Comparison of platelet activity measurements by use of arterial and venous blood sampling.
Shah B, Sedlis SP, Mai X, Amoroso NS, Guo Y, Lorin JD, Berger JS
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine whether differences in platelet counts, MPV, IPF, MPA, and LPA exist between venous and arterial blood and whether soluble P-selectin levels differ between plasma from venous and arterial blood. Sodium citrate plasma was frozen at -80 degrees C prior to soluble P-selectin analysis. Blood specimens intended for all other analyses were collected into K2EDTA and analyzed within one hour.
Summary of Findings
Venous and arterial blood showed strong to very strong correlations in platelet counts, MPV, IPF, and LPA, but MPA in blood and soluble P-selectin levels in plasma were only modestly correlated between the two types of specimens (rho=0.65 and 0.68, respectively). For both of these analytes, median values were higher among the venous specimens than the arterial specimens.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)FrozenDiagnoses
Diabetes Type 1Diabetes Type 2Coronary Artery DiseaseNormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometryProteinELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw ArteryVeinBiospecimen Aliquots and Components Blood and blood products PlasmaWhole bloodBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)