Skip to main content

Serum, plasma, and dried blood spot high-sensitivity C-reactive protein enzyme immunoassay for population research.

Brindle E, Fujita M, Shofer J, O'Connor KA

Publication: J Immunol Methods (2010) • Vol 362 • Page 112-20PMID: 20850446View on PubMed

Purpose

The purpose of this paper was to determine the effects of analysis of dried blood spots (DBS) versus liquid serum or plasma, collection of venous versus capillary blood, and storage of specimens at room temperature or -20 degrees C on C-reactive protein (CRP) levels.

Conclusion

Very strong correlations were observed between CRP measurements from plasma, serum, venous DBS, and capillary DBS, but DBS had the lowest average levels of CRP while serum had the highest. CRP showed significant declines after capillary DBS were subjected to 8 freeze-thaw cycles, stored at 22 degrees C for 14 d or more, stored at 37 degrees C for 7 d or more, or during hot cycling after 12 h at 37 degrees C followed by 12 h at 15 degrees C. On the other hand, CRP was stable in capillary DBS stored at -20 degrees C for up to 42 d. During long-term frozen storage (lasting between 161 and 1026 d at -20 degrees C), CRP declined significantly in venous DBS but not in serum. Among field-collected specimens, ambient temperature storage of more than 20 d prior to frozen storage had a detrimental effect on CRP levels in DBS.

Studies (2)

Purpose

The purpose of this study was to determine the effects of analysis of DBS versus liquid serum or plasma and collection of venous versus capillary blood on CRP levels. Plasma was prepared from venous blood collected into K2EDTA tubes. Serum was prepared from venous blood collected into plain tubes. A second plain tube of venous blood was used to prepare venous DBS, while a fingerprick specimen was used to prepare capillary DBS. Both DBS were dried at room temperature for 3-5 hours, stored in sealed bags with desiccant, and frozen at -20 degrees C along with serum and plasma specimens.

Summary of Findings

Significant correlations were observed between CRP measurements from plasma, serum, venous DBS, and capillary DBS (0.974-0.995). Plasma levels of CRP were on average 7% lower than those in serum. CRP levels were only an average of 1% lower in venous DBS than capillary DBS, but they were 33% and 31% lower, on average, respectively, than CRP levels measured in serum. The authors report that their CRP assay results did not differ significantly from those determined with a previously published assay method.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    FrozenOther Preservative
  • Diagnoses

    Not specified
  • Platforms

    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen