Skip to main content

Overnight, room temperature hold of whole blood followed by 42-day storage of red blood cells in additive solution-7.

Dumont LJ, Cancelas JA, Maes LA, Rugg N, Whitley P, Herschel L, Siegal AH, Szczepiorkowski ZM, Hess JR, Zia M

Publication: Transfusion (2014) • Vol 55(3) • Page 485-90PMID: 25234026View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed processing of blood, red blood cell (RBC) storage solution and refrigeration duration on markers of RBC quality.

Conclusion

Storage of blood in additive solution (AS)-7 before processing into RBCs affected pH, morphology scores and lactate levels. Once processed into RBCs, storage solution affected hematocrit (Hct), bicarbonate, and glucose, and refrigerated storage duration affected pH, bicarbonate, glucose, adenosine triphosphate (ATP), lactate and hemolysis rate.

Studies (1)

Purpose

The purpose of this study was to determine the effects of delayed processing of blood, RBC storage solution and refrigeration duration on markers of RBC quality.  RBCs in AS-7 (also called SOLX) were obtained from blood stored 0-2 h, 6-8 h or 18-24 h using the LEUKOSEP HWB-600-XL filter, and RBCs in AS-1 were obtained from blood stored 6-8 h using the RZ2000 leukoreduction filter.

Summary of Findings

Regardless of processing delays or storage solution, the RBC pH, bicarbonate, glucose and ATP levels decreased, and lactate and hemolysis rate increased with increased storage duration. Immediately after processing, Hct, bicarbonate and glucose were lower in RBCs in AS-1 than AS-7, but mean corpuscular volume (MCV) was comparable. The Hct in AS-1 units remained constant during storage but the Hct of RBCs in AS-7 declined with storage. On day 42 of refrigerated storage, RBCs from blood held overnight before processing into AS-7 had higher ATP levels and fewer RBC microvesicles than RBCs from blood held for 6-8 h before processing into AS-1. When stored overnight before processing into RBCs in AS-7, the pH was lower and lactate higher, but ATP, bicarbonate, and glucose levels were comparable to those of RBCs processed into AS-7 after 8h or less. Further, after refrigerated storage of RBC, morphology scores were lower in RBCs processed after 16-24 h than those processed after <8 h, but there was no effect on potassium leakage or RBC microvesicles, and the effect on pH was no longer noticeable.

  • Biospecimens

    CellRed Blood Cells
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeClinical chemistry/auto analyzer
    MorphologyHematology/ auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood processing method
    LEUKOSEP HWB-600-XL leukoreduction filter
    RZ2000 leukoreduction filter
    StorageShort-term storage solution
    AS-1
    AS-7 (SOLX)
    StorageStorage duration
    0 days
    42 days
    56 days
    StorageTime at room temperature
    0-2 h
    18-24 h
    6-8 h