Clinical evaluation of a dried blood spot method for determination of mycophenolic acid in renal transplant patients.

Arpini J, Antunes MV, Pacheco LS, Gnatta D, Rodrigues MF, Keitel E, Linden R

Publication: Clin Biochem (2013) • Vol 46(18) • Page 1905-8PMID: 24161478View on PubMed

Purpose

The purpose of this paper was to determine the effects of using dried blood spots (DBS) from fingerprick blood rather than frozen EDTA plasma obtained by venipuncture to determine levels of mycophenolic acid (MPA) in blood from renal transplant patients.

Conclusion

Levels of MPA in DBS from fingerprick blood were very strongly correlated with those in frozen plasma obtained by venipuncture, but on average, levels were 39.3% lower in the DBS. However, using the hematocrit, the authors were able to determine estimated plasma concentrations (EPC) for DBS specimens, and these values were, on average, 102.2% of the matched plasma values. Correction of DBS values using a mean hematocrit, rather than individual measurements, led to EPC values that were 103.4% of those in plasma.

Studies (1)

Purpose

The purpose of this study was to determine the effects of using DBS from fingerprick blood rather than frozen EDTA plasma obtained by venipuncture to determine levels of MPA in blood from renal transplant patients. Blood spots were dried for 3 h before placement in plastic bags in which they were stored at room temperature for up to 48 h before analysis. EDTA plasma was obtained by standard venipuncture and centrifugation and stored at -20 degrees C.

Summary of Findings

Levels of MPA in DBS from fingerprick blood were very strongly correlated with those in frozen plasma obtained by venipuncture (r=0.9901), but on average, levels were only 60.7% of those in frozen plasma obtained by venipuncture. However, using the hematocrit, the authors were able to determine EPC for DBS specimens, and these values were, on average, 102.2% of the matched plasma values. Correction of DBS values using a mean hematocrit, rather than individual measurements, led to EPC values that were 103.4% of those in plasma.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Other PreservativeFrozen
  • Diagnoses

    Other diagnoses
  • Platforms

    Small moleculeHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Renal transplant patient
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Finger/heel prick sampling
    Venipuncture
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen