Skip to main content

Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor.

Lagerberg JW, Salado-Jimena JA, Löf H, Bontekoe IJ, Nielsen C, Verheggen C, van Waeg G, Van der Meer PF, de Korte D, Hansen MB, Knutson F

Publication: Transfusion (2013) • Vol 53 • Page 1798-807PMID: 23228178View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed processing of blood into red blood cells (RBCs), plasma and interim platelet (Plt) units (IPU), and using the Reveos 2C or 3C machine rather than the buffy coat method for component separation on markers of component quality during subsequent storage of RBCs at 4 degrees C and IPUs at room temperature.

Conclusion

When separation was completed by Reveos 2C or 3C, RBCs had significantly higher hemoglobin (Hb) levels, and recovered plasma had lower RBC and white blood cell (WBC) counts than when separation was by the buffy coat method. Processing delay-dependent effects of using the Reveos 2C or 3C rather than the buffy coat method were identified for RBC recovery, Factor (F)IX levels, activated partial thromboplastin time (APTT) and prothrombin time (PT). Thrombin-antithrombin (TAT) and prothrombin fragment 1+2 (PF1.2) were not significantly different between Reveos 2C plasma and buffy-coat plasma. While TAT values were in the reference range for all buffy coat-processed specimens obtained after a delay of 2-8 h, they were above the reference range for 35% of Reveos 2C-produced plasma. FVIII levels in plasma and glucose levels in Plts were lower when blood specimens were held for 10-24 h before processing than when the delay was only 2-8 h. With increasing refrigerated storage of RBCs, extracellular potassium and the percentage of hemolysis increased. The increase in intracellular potassium during storage was slightly larger in RBCs obtained by Reveos 2C than those obtained by the buffy coat method, but no other clinically relevant, processing-dependent effects of storage of RBCs were identified. During room temperature Plt storage, glucose decreased, lactate increased and pH and swirl effect remained constant, regardless of delay in processing or processing method.

Studies (3)

Purpose

The purpose of this study was to determine the effects of delayed separation of RBCs, and using a Reveos 2C or 3C machine rather than the buffy coat processing method on markers of RBC quality during subsequent refrigerated storage of RBCs. Citrate-phosphate-dextrose (CPD) anticoagulated blood was actively cooled to 20-24 degrees C on 1,4-butane-diol plates and held for 2-8 or 10-24 h before processing into RBCs in saline-adenine-glucose-mannitol (SAGM). Values for buffy coat-processed units were adjusted to account for volume differences between processing methods. The effects of refrigerated storage of RBCs were only assessed using RBCs produced by the buffy coat method or the Reveos 2C. The buffy coat method involved a hard centrifuge followed by automated separation, whereas the Reveos utilized a computer-controlled centrifuge.

Summary of Findings

RBCs obtained by Reveos 2C or 3C had significantly higher Hb levels compared to RBCs obtained by the buffy coat method (p<0.05, both), regardless of room temperature delays prior to separation. When blood was held for only 2-8 h prior to processing, the RBC recovery was higher using Reveos 2C than the buffy coat method (88% versus 82%, p<0.05), but this difference was not present when blood processing was delayed by 10-24 h. The authors report no effect of delayed processing on the cellular composition of RBCs obtained with the Reveos 3C. With increasing refrigerated storage of RBCs, extracellular potassium, and the percentage of hemolysis increased. The increase in intracellular potassium during refrigerated storage was slightly larger in RBCs obtained by Reveos 2C than the buffy coat method, but there was no effect of room temperature delays prior to processing on extracellular potassium levels during storage. Initially, hemolysis was slightly higher in Reveos 2C-processed RBCs held for 10-24 h than RBCs processed by the buffy coat method after 2-8 h, but the increase in hemolysis during refrigerated storage was comparable between all groups, and hemolysis remained below 0.8%. Adenosine triphosphate (ATP) levels increased between day 0 and day 14 but subsequently decreased with some small, non-clinically relevant differences noted between groups.

  • Biospecimens

    CellRed Blood Cells
    FluidBlood
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    Cell count/volumeFlow cytometry
    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinSpectrophotometry
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood processing method
    Buffy-coat method
    Reveos 2C
    Reveos 3C
    Biospecimen Aliquots and ComponentsCentrifugation
    Automated
    Manual
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    Refrigeration
    StorageStorage duration
    0 days
    14 days
    28 days
    42 days
    StorageTime at room temperature
    10-24 h
    2-8 h