Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor.
Lagerberg JW, Salado-Jimena JA, Löf H, Bontekoe IJ, Nielsen C, Verheggen C, van Waeg G, Van der Meer PF, de Korte D, Hansen MB, Knutson F
Purpose
Conclusion
Studies (3)
Purpose
The purpose of this study was to determine the effects of delayed separation of RBCs, and using a Reveos 2C or 3C machine rather than the buffy coat processing method on markers of RBC quality during subsequent refrigerated storage of RBCs. Citrate-phosphate-dextrose (CPD) anticoagulated blood was actively cooled to 20-24 degrees C on 1,4-butane-diol plates and held for 2-8 or 10-24 h before processing into RBCs in saline-adenine-glucose-mannitol (SAGM). Values for buffy coat-processed units were adjusted to account for volume differences between processing methods. The effects of refrigerated storage of RBCs were only assessed using RBCs produced by the buffy coat method or the Reveos 2C. The buffy coat method involved a hard centrifuge followed by automated separation, whereas the Reveos utilized a computer-controlled centrifuge.
Summary of Findings
RBCs obtained by Reveos 2C or 3C had significantly higher Hb levels compared to RBCs obtained by the buffy coat method (p<0.05, both), regardless of room temperature delays prior to separation. When blood was held for only 2-8 h prior to processing, the RBC recovery was higher using Reveos 2C than the buffy coat method (88% versus 82%, p<0.05), but this difference was not present when blood processing was delayed by 10-24 h. The authors report no effect of delayed processing on the cellular composition of RBCs obtained with the Reveos 3C. With increasing refrigerated storage of RBCs, extracellular potassium, and the percentage of hemolysis increased. The increase in intracellular potassium during refrigerated storage was slightly larger in RBCs obtained by Reveos 2C than the buffy coat method, but there was no effect of room temperature delays prior to processing on extracellular potassium levels during storage. Initially, hemolysis was slightly higher in Reveos 2C-processed RBCs held for 10-24 h than RBCs processed by the buffy coat method after 2-8 h, but the increase in hemolysis during refrigerated storage was comparable between all groups, and hemolysis remained below 0.8%. Adenosine triphosphate (ATP) levels increased between day 0 and day 14 but subsequently decreased with some small, non-clinically relevant differences noted between groups.
Biospecimens
CellRed Blood CellsFluidBloodPreservation Types
Other PreservativeNone (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometryElectrolyte/MetalClinical chemistry/auto analyzerProteinSpectrophotometrySmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method Buffy-coat methodReveos 2CReveos 3CBiospecimen Aliquots and Components Centrifugation AutomatedManualBiospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Storage duration 0 days14 days28 days42 daysStorage Time at room temperature 10-24 h2-8 h
Purpose
The purpose of this study was to determine the effects of delayed separation of plasma, and using a Reveos 2C or 3C machine rather than the buffy coat processing method on markers of plasma quality. CPD anticoagulated blood was actively cooled to 20-24 degrees C on 1,4-butane-diol plates and held for 2-8 or 10-24 h before processing into plasma. Values for buffy coat-processed units were adjusted to account for volume differences between processing methods. Plasma was stored at -25 degrees C for at least 1 month, thawed at 37 degrees C, sampled and then the remainder was snap-frozen until analysis. The buffy coat method involved a hard centrifuge followed by automated separation, whereas the Reveos utilized a computer-controlled centrifuge.
Summary of Findings
Regardless of the delay to processing, compared to the buffy coat method, plasma recovery was higher and Plt counts were lower using the Reveos 2C (p<0.05, both), but plasma recovery was lower and Plt counts were higher using the Reveos 3C (p<0.05, both). Plasma obtained by Reveos 2C or 3C had lower RBC and WBC counts than plasma obtained by the buffy coat method (p<0.05, all). Regardless of processing method, FVIII levels were lower in plasma from blood subjected to a 10-24 h room temperature processing delay than those delayed for 2-8 h (p<0.05). When processed within 2-8 h, plasma obtained by Reveos 2C had lower FIX levels and longer APTT and PT than plasma obtained by the buffy coat method (p<0.05, all), but these differences were not present after 10-24 h processing delays. TAT and PF1.2 were not significantly higher in Reveos 2C plasma than buffy coat plasma. While TAT values were in the reference range for all buffy coat-processed specimens obtained after a delay of 2-8 h, 35% of the Reveos 2C-produced plasma units from blood subjected to a 2-8 h processing delay had TAT values above the reference values. Further, 60% of plasma specimens obtained after a delay of 10-24 h had TAT above the reference range, regardless of processing method.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
Cell count/volumeLight microscopyMorphologyHematology/ auto analyzerMorphologyColorimetric assayProteinColorimetric assayProteinELISAGlycoproteinColorimetric assayPeptideELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method Buffy-coat methodReveos 2CReveos 3CBiospecimen Aliquots and Components Centrifugation AutomatedCentrifugation delays investigatedManualStorage Time at room temperature 10-24 h2-8 h
Purpose
The purpose of this study was to determine the effects of delayed separation of RBCs, and using a Reveos 2C or 3C machine rather than the buffy coat processing method on markers of RBC quality during subsequent refrigerated storage of RBCs. Citrate-phosphate-dextrose (CPD) anticoagulated blood was actively cooled to 20-24 degrees C on 1,4-butane-diol plates and held for 2-8 or 10-24 h before processing into RBCs in saline-adenine-glucose-mannitol (SAGM). Values for buffy coat-processed units were adjusted to account for volume differences between processing methods. The effects of refrigerated storage of RBCs were only assessed using RBCs produced by the buffy coat method or the Reveos 2C. The buffy coat method involved a hard centrifuge followed by automated separation, whereas the Reveos utilized a computer-controlled centrifuge.
Summary of Findings
The leukopack obtained using the Reveos 2C was smaller and had less plasma, RBCs and Plts than what was obtained using the buffy coat method. When blood was held for 2-8 h before processing in the Reveos 3C, 17 of 64 (18%) IPU's had insufficient Plt yield for pooling, and when held for 10-24 h, only 3 of 64 (5%) had insufficient Plt yield. During room temperature storage of Plts, glucose decreased, lactate increased and pH and swirl effect remained constant, regardless of delay in processing or processing method. Initial glucose levels were lower in specimens subjected to a 10-24 h delay in processing than those subjected to a 2-8 h delay. Thromboelastographic (TEG) properties and the percentage of CD62P-positive cells were not affected by processing method or room temperature storage of Plts.
Biospecimens
CellRed Blood CellsFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
GasClinical chemistry/auto analyzerMorphologyMacroscopic observationCell count/volumeHematology/ auto analyzerCell count/volumeClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerMorphologyThromboelastographyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method Buffy-coat methodReveos 2CReveos 3CBiospecimen Aliquots and Components Centrifugation AutomatedManualStorage Storage duration 2 days5 days7 daysStorage Time at room temperature 10-24 h2-8 h