Random variation and systematic error caused by various preanalytical variables, estimated by linear mixed-effects models.
Sylte MS, Wentzel-Larsen T, Bolann BJ
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of transporting blood specimens by PTS rather than hand-delivery on levels of 22 clinical chemistry analytes in serum. 4 blood specimens were collected from 60 non-fasting patients at the outpatient clinic. Blood was collected through 21-gauge straight needles into serum separator gel tubes which were inverted 5 times and stored for 10 min before transport. Prior to transport by PTS, specimens were wrapped in bubble wrap. Both transport by PTS and hand-delivery took 2.5 min.
Summary of Findings
Specimens transported by PTS had significantly higher LD (p<0.001) and magnesium levels (p=0.003) than specimens transported by hand-delivery. Further, the SDs in creatinine kinase and glucose levels were higher when specimens were transported by PTS than hand-delivered.
Biospecimens
FluidBloodFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Within hospital transportation method Hand-deliveredPneumatic tube system
Purpose
The purpose of this study was to determine the effects of collection needle type and gauge and inverting the tube once rather than 5 times on levels of 22 clinical chemistry analytes in serum. 4 blood specimens were collected from 60 seated, non-fasting patients at the outpatient clinic. After <1 min tourniquet time, blood was collected into serum separator tubes first through a 21-gauge straight needle from one arm and then through a 23-gauge butterfly needle using the other arm. One tube collected from each arm was inverted 5 times while the other tube was inverted only once.
Summary of Findings
Serum from blood collected using 23-gauge butterfly needles had lower levels of calcium (p=0.02) and creatinine kinase (p=0.021) than serum from blood collected through 21-gauge straight needles. The SDs of ALP and LD were also higher in specimens collected through 23-gauge butterfly needles than in those collected through 21-gauge straight needles. When specimens with an H-index >40 were excluded, LD levels were significantly lower in serum from blood collected through 23-gauge butterfly needles than serum from blood collected through 21-gauge straight needles (p=0.047), but the LD SD was not affected by needle type and gauge. Iron levels were higher when specimens were inverted only once rather than five times (p=0.009), but the SD and other analytes were not significantly affected.
Biospecimens
FluidBloodFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Butterfly deviceNeedleBiospecimen Acquisition Needle gauge 21-gauge23-gaugeBiospecimen Aliquots and Components Biospecimen mixing Inverted 5-6 timesInverted once