A stabilizing reagent prevents cell-free DNA contamination by cellular DNA in plasma during blood sample storage and shipping as determined by digital PCR.

Norton SE, Lechner JM, Williams T, Fernando MR

Publication: Clin Biochem (2013) • Vol 46 • Page 1561-5PMID: 23769817View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection, storage and transport of whole blood in Streck BCT tubes (BCT) rather than K3 EDTA tubes on levels of cell-free and genomic DNA in plasma.

Conclusion

When whole blood was stored in K3 EDTA tubes at room temperature, significant increases in cell-free and genomic DNA were noted in plasma on day 2 and day 1, respectively. However, when whole blood was stored at room temperature in BCT tubes, plasma levels of cell-free and genomic DNA were stable for 7 days, but they were higher after 14 days than on day 0. When whole blood was shipped round-trip by air in K3EDTA tubes, cell-free and genomic DNA levels in plasma were higher than prior to shipment (p=0.0011 and 0.0157, respectively), but levels of cell-free and genomic DNA in plasma were not affected by shipment in BCT tubes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection, storage and transport of whole blood in BCT rather than K3 EDTA tubes on levels of cell-free and genomic DNA in plasma. Research was conducted at the manufacturer of the BCT tubes. Blood was shipped round-trip in insulated boxes by overnight air freight between Omaha and Lincoln, Nebraska. DNA was extracted with QIAamp Circulating Nucleic Acid Kit and stored at -60 degrees C until analysis. DNA was quantified by digital PCR amplification of a 136 bp (cell-free DNA) and 420 bp (genomic DNA) fragments of beta actin.

Summary of Findings

When whole blood was stored in K3 EDTA tubes at room temperature, significant increases in cell-free and genomic DNA were noted in plasma on day 2 (2 fold, p=0.0092) and day 1 (1.2 fold, p=0.037), respectively, compared to day 0. However, when whole blood was stored at room temperature in BCT tubes, plasma levels of cell-free and genomic DNA were stable for 7 days, but after 14 days, they were 4 (p<0.0001) and 1.9 fold (p<0.02) higher, respectively, than on day 0. When whole blood was shipped round-trip by air in K3EDTA tubes, cell-free and genomic DNA levels in plasma were higher than prior to shipment (p=0.0011 and 0.0157, respectively), but levels of cell-free and genomic DNA were not affected by shipment in BCT tubes.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)Streck/BCT
  • Diagnoses

    Normal
  • Platforms

    DNADigital PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    K3EDTA vacutainer
    Streck BCT
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Biospecimen PreservationType of fixation/preservation
    Blood collection tube additive
    None (fresh)
    StorageBetween site transportation method
    Air courier
    Not transported
    StorageTime at room temperature
    0 days
    1 day
    14 days
    2 days
    3 days
    7 days
    Digital PCR SpecificTargeted nucleic acid
    Beta-actin