Pseudohyperkalemia due to pneumatic tube transport in a leukemic patient.
Kellerman PS, Thornbery JM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of anticoagulant choice, collection container type and transport of blood specimens by PTS on potassium levels in plasma from patients with leukocytosis and patients with normal WBC counts. Within a 25 min timeframe, blood was drawn from a single patient with leukocytosis into: Two lithium heparin vacutainers, one of which was transported by PTS, and another was hand-delivered, and three arterial blood gas syringes, two of which contained heparin, and one with lithium heparin, all of which were hand-delivered. Blood was collected from 5 patients with normal WBC counts and transported by PTS of hand delivered. No statistical analysis was presented.
Summary of Findings
When blood from the patient with leukocytosis was transported by PTS in a lithium heparin vacutainer, 2-3 fold higher plasma potassium levels were measured than when blood from the same patient was hand-delivered. However, PTS transport of whole blood had no effects on the levels of potassium in plasma from patients with normal WBC counts. Among specimens from the patient with leukocytosis, plasma potassium levels were unaffected by drawing blood into a syringe rather than a vacutainer or collection into lithium heparin versus heparin.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
Not specifiedOther diagnosesPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition LeukocytosisPatient with normal WBC countBiospecimen Acquisition Anticoagulant HeparinLithium heparinBiospecimen Acquisition Type of collection container/solution Arterial blood gas syringeVacutainerStorage Within hospital transportation method Hand-deliveredPneumatic tube system