Purpose

The purpose of this paper was to determine the effects of refrigerated storage on the analytical variability of 47 hematology and clinical chemistry analytes measured in blood.

Conclusion

For 15 of the 47 analytes, more than 10% of the variability in measured levels could be attributed to refrigerated storage of blood specimens, and for another 9 analytes, 5% or more of the variability in levels was attributable to refrigerated storage.

Studies (1)

Purpose

The purpose of this study was to determine the effects of refrigerated storage of blood on the analytical variability of 47 hematology and clinical chemistry analytes. 40 blood specimens from healthy individuals were refrigerated for up to 36 h before frozen storage at an unspecified temperature. 19 of the 47 analytes were measured at all 4 time-points and the remaining 28 were only measured at 0 and 24 h.

Summary of Findings

More than 10% of the variance in levels of bicarbonate (61%), albumin (38%), mean corpuscular hemoglobin (36%), total protein (35%), potassium (30%), basophils (28%), eosinophils (16%), calcium (15%), packed cell volume (15%), hemoglobin (14%), hemoglobin A1c (14%), sodium (13%), red blood cells (12%), chloride (11%), and platelet counts (11%) was attributable to refrigerated storage. 5% or more of the variability in hemoglobin A1cx (10%), glucose (8%), bilirubin (7%), glucose F oxalate (7%), magnesium (6%), lymphocytes (5%), insulin (5%), cholesterol (5%) and monocytes (5%) was attributable to refrigerated storage. For the remaining 22 analytes, <5% of the variability in measured levels was attributable to refrigerated storage of specimens. Further, due to the variability attributed to storage, reliable measurements of bicarbonate, albumin, total protein, basophils and magnesium required the sample size to be more than doubled.

  • Biospecimens

    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    GlycoproteinClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    0 h
    12 h
    24 h