Skip to main content

Effect of pneumatic tube delivery system rate and distance on hemolysis of blood specimens.

Eviyaoglu O, Toprak G, Tekin A, Basarali M, Kilinç C, Colpan L

Publication: J Clin Lab Anal (2012) • Vol 26 • Page 66-9PMID: 22467320View on PubMed

Purpose

The purpose of this paper was to determine the effects of anticoagulant type, pneumatic tube system (PTS) transport, PTS speed and duration, and centrifugation before or after transport on lactate dehydrogenase (LDH) and potassium (K) levels and markers of blood quality in plasma and serum.

Conclusion

K and LDH levels were higher in some plasma and serum specimens when whole blood was transported by PTS rather than hand-delivered, and the magnitude of the effects increased with increasing distance travelled and speed of transport. Changes in LDH and K tended to be larger in plasma that was anticoagulated with citrate than heparinated plasma, and changes in LDH and K due to PTS transport also tended to be higher in plasma than serum, but significance was not evaluated. When blood was centrifuged prior to PTS transport, and serum was transported, the LDH and K levels were comparable to levels measured in hand-delivered specimens. Transport by PTS did not affect cell counts, prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen levels or markers of platelet activation.

Studies (1)

Purpose

The purpose of this study was to determine the effects of anticoagulant type, PTS transport, PTS speed and duration, and centrifugation before or after transport on LDH and K levels and markers of blood quality in serum and plasma.

Summary of Findings

K and LDH levels were higher in some plasma and serum specimens when whole blood was transported by PTS rather than hand-delivered (p<0.05), and the magnitude of the effects increased with increasing distance travelled and speed of transport. Changes in LDH and K tended to be larger in plasma that was anticoagulated with citrate than in heparinated plasma, and PTS transport-related increased in K and LDH tended to be higher in plasma than serum, but significance was not evaluated. When blood was centrifuged prior to PTS transport, and serum was transported instead of whole blood, the LDH and K levels were comparable to levels measured in hand-delivered specimens. Moderate to strong correlations between K and LDH levels and distance travelled by PTS were observed in plasma (r=0.628-0.716) and serum (r=0.774-0.871), depending on transport speed. Transport by PTS did not affect cell counts, PT, aPTT, fibrinogen levels or markers of platelet activation.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Citrate
    Heparin
    None
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageSpecimen transport duration/condition
    1100 m
    1380 m
    1450 m
    2200 m
    2900 m
    3.1 m/sec
    4.2 m/sec
    500 m
    Centrifuged
    Uncentrifuged
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system