Pseudohyperkalaemia associated with leukaemic cell lysis during pneumatic tube transport of blood samples.

Dickinson H, Webb NJ, Chaloner C, Wynn RF, Bonney DK

Publication: Pediatr Nephrol (2012) • Vol 27 • Page 1029-31PMID: 22366875View on PubMed

Purpose

The purpose of this paper was to determine the effects of pneumatic tube system (PTS) transport of blood on levels of potassium in whole blood and plasma.

Conclusion

Potassium levels were approximately 2-fold higher when blood was transported to the laboratory via PTS rather than hand-delivered, regardless of whether lithium-heparin plasma was analyzed with the COBAS 800 or whole blood was analyzed with the ABL 827.

Studies (1)

Purpose

The purpose of this study was to determine the effects of PTS transport of blood on levels of potassium in whole blood and plasma.

Summary of Findings

Potassium levels were approximately 2-fold higher when blood was transported to the laboratory via PTS rather than hand-delivered, regardless of whether lithium-heparin plasma was analyzed with the COBAS 800 or whole blood was analyzed with the ABL 827.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system
    Clinical chemistry/auto analyzer SpecificTechnology platform
    ABL 827
    COBAS 800