The purpose of this paper was to determine the effects of storage of plasma at 8°C, storage of serum and plasma at -80°C, and freeze-thaw cycling of serum on the recovery of added vitamin B6 vitamers pyridoxamine-5_-phosphate (PMP), pyridoxamine (PM), pyridoxal 5_-phosphate (PLP), pyridoxal (PL), and pyridoxine (PN) and the vitamin B6 metabolite 4-pyridoxic acid (4-PA).
Application of the high-performance liquid chromatography method with coulometric detection for determination of vitamin B(6) in human plasma and serum.
Marszałł ML, Lebiedzińska A, Czarnowski W, Makarowski R, Kłos M, Szefer P
Purpose
Conclusion
When spiked plasma specimens were stored at 8°C, vitamer and 4-PA levels declined by an average of 4% after 12 h and 14.2% after 24 h. However, up to 2 months of storage at -80°C had no effect on the recovery of added vitamin B6 vitamers or 4-PA in plasma or serum. Up to 3 freeze-thaw cycles had no effect on levels of vitamin B6 vitamers or 4-PA in spiked serum. Levels of PLP, PL, PN, and 4-PA tended to be higher in females than males.
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage of plasma at 8°C, storage of serum and plasma at -80°C, and freeze-thaw cycling of serum on the recovery of added vitamin B6 vitamers PMP, PM, PLP, PL, and PN and the vitamin B6 metabolite 4-PA. To investigate vitamer stability during frozen storage and freeze-thaw cycling, 3-5 pools of serum or plasma were spiked with 3 different concentrations of PMP, PM, PLP, PL, PN and 4-PA. Freeze-thaw cycling protocol consisted of freezing specimens at -80°C, thawing at room temperature for 30 min, and storage at 8°C for 30 min before analysis or refreezing. Gender differences were observed using specimens from 40 Polish individuals without diabetes, metabolic disorders or heart disease.
Summary of Findings
Recovery of added vitamin B6 vitamers and 4-PA ranged from 90.4-98.4% in plasma and serum. When spiked plasma specimens were stored at 8°C, vitamer and 4-PA levels declined by an average of 4% after 12 h and 14.2% after 24 h. However, up to 2 months of storage at -80°C had no effect on the recovery of added vitamin B6 vitamers or 4-PA in plasma or serum. Up to 3 freeze-thaw cycles had no effect on levels of vitamin B6 vitamers or 4-PA in spiked serum. Levels of PLP, PL, PN, and 4-PA tended to be higher in females than males.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
Small moleculeHPLCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Biospecimen components 24.5 - 182.5 nM 4-PA24.5 - 182.5 nM PL24.5 - 182.5 nM PLP24.5 - 182.5 nM PM24.5 - 182.5 nM PMP24.5 - 182.5 nM PNStorage Freeze/thaw cycling 0 cycles1 cycle2 cycles3 cyclesStorage Storage duration 0 h1 week12 h18 h2 weeks24 h3 weeks4 weeks5 weeks6 h6 weeks7 weeks8 weeksStorage Storage temperature -80°C8°C