Skip to main content

Application of the high-performance liquid chromatography method with coulometric detection for determination of vitamin B(6) in human plasma and serum.

Marszałł ML, Lebiedzińska A, Czarnowski W, Makarowski R, Kłos M, Szefer P

Publication: J Chromatogr B Analyt Technol Biomed Life Sci (2009) • Vol 877 • Page 3151-8PMID: 19733133View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage of plasma at 8°C, storage of serum and plasma at -80°C, and freeze-thaw cycling of serum on the recovery of added vitamin B6 vitamers pyridoxamine-5_-phosphate (PMP), pyridoxamine (PM), pyridoxal 5_-phosphate (PLP), pyridoxal (PL), and pyridoxine (PN) and the vitamin B6 metabolite 4-pyridoxic acid (4-PA).

Conclusion

When spiked plasma specimens were stored at 8°C, vitamer and 4-PA levels declined by an average of 4% after 12 h and 14.2% after 24 h. However, up to 2 months of storage at -80°C had no effect on the recovery of added vitamin B6 vitamers or 4-PA in plasma or serum. Up to 3 freeze-thaw cycles had no effect on levels of vitamin B6 vitamers or 4-PA in spiked serum. Levels of PLP, PL, PN, and 4-PA tended to be higher in females than males.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage of plasma at 8°C, storage of serum and plasma at -80°C, and freeze-thaw cycling of serum on the recovery of added vitamin B6 vitamers PMP, PM, PLP, PL, and PN and the vitamin B6 metabolite 4-PA. To investigate vitamer stability during frozen storage and freeze-thaw cycling, 3-5 pools of serum or plasma were spiked with 3 different concentrations of PMP, PM, PLP, PL, PN and 4-PA. Freeze-thaw cycling protocol consisted of freezing specimens at -80°C, thawing at room temperature for 30 min, and storage at 8°C for 30 min before analysis or refreezing. Gender differences were observed using specimens from 40 Polish individuals without diabetes, metabolic disorders or heart disease.

Summary of Findings

Recovery of added vitamin B6 vitamers and 4-PA ranged from 90.4-98.4% in plasma and serum. When spiked plasma specimens were stored at 8°C, vitamer and 4-PA levels declined by an average of 4% after 12 h and 14.2% after 24 h. However, up to 2 months of storage at -80°C had no effect on the recovery of added vitamin B6 vitamers or 4-PA in plasma or serum. Up to 3 freeze-thaw cycles had no effect on levels of vitamin B6 vitamers or 4-PA in spiked serum. Levels of PLP, PL, PN, and 4-PA tended to be higher in females than males.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Small moleculeHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen Aliquots and ComponentsBiospecimen components
    24.5 - 182.5 nM 4-PA
    24.5 - 182.5 nM PL
    24.5 - 182.5 nM PLP
    24.5 - 182.5 nM PM
    24.5 - 182.5 nM PMP
    24.5 - 182.5 nM PN
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    StorageStorage duration
    0 h
    1 week
    12 h
    18 h
    2 weeks
    24 h
    3 weeks
    4 weeks
    5 weeks
    6 h
    6 weeks
    7 weeks
    8 weeks
    StorageStorage temperature
    -80°C
    8°C