Effect of storage on the apparent concentration of folate in erythrocytes, as measured by competitive protein binding radioassay.

Mortensen E

Publication: Clin Chem (1978) • Vol 24 • Page 663-8PMID: 639272View on PubMed

Purpose

The purpose of this paper was to determine the effects of hematocrit, hemolysis, anticoagulant and storage solution on levels of folate in whole blood and washed red blood cells.

Conclusion

Folate levels in blood and washed red blood cells were stable when stored at 4°C for 72 h, but when stored at 37°C, levels declined by ~50% in whole blood after 48 h and increased >2 fold in red blood cells after 72 h. The levels of folate in whole blood and red blood cells were affected by hematocrit, hemolysis, the presence of ascorbic acid, acetylphenylhydrazine, or iodoacetate, replacement of plasma with buffer, or replacement of red blood cell buffer with plasma, heat inactivated plasma or plasma ultrafiltrate. Neither the presence of glucose in red blood cell buffer nor the choice of anticoagulant (EDTA versus heparin or sodium fluoride) had effects on folate levels.

Studies (1)

Purpose

The purpose of this study was to determine the effects of hematocrit, hemolysis, anticoagulant and storage solution on levels of folate in whole blood and washed red blood cells. Blood was obtained from 12 healthy donors, but only 3 specimens were used to determine the effect of hemolysis, hematocrit and most additives. The authors provide no details for the hemolysis experiment. Whole blood and erythrocytes washed in a buffer containing glucose were obtained from 6 blood donors.

Summary of Findings

Folate levels in blood and washed red blood cells were stable when stored at 4°C for 72 h, but when stored at 37°C, levels declined by ~50% in whole blood after 48 h and increased >2 fold in red blood cells after 72 h. When hematocrit of 3 blood specimens was adjusted to different levels, the decline in folate was greater in specimens with a higher hematocrit such that by 72 h, folate levels in 2 of 3 specimens with a high hematocrit were comparable to those in specimens with a low hematocrit. A slight increase in the decline in folate levels with incubation at 37°C was noted when hemolysate was added. The decline in folate levels in whole blood stored at 37°C was partially attenuated when 5 mg/mL ascorbic acid was added to blood. When 50% of the plasma was removed from whole blood and replaced with buffer containing glucose, the folate levels in blood increased with storage at 37°C, but the increase was less than that observed in red blood cells. When erythrocytes were incubated at 37°C in plasma, a plasma ultrafiltrate or heat-inactivated plasma, folate declined during storage, but when red blood cells were incubated in equal parts plasma and buffer, folate levels increased with storage. Glucose in the buffer had no effect on the increase in folate in red blood cells. Anticoagulant choice (EDTA versus heparin or sodium fluoride) had no effect on the decrease in folate with storage of whole blood at 37°C, but the addition of iodoacetate led to a steeper decline in folate levels in whole blood and attenuated the increase in folate in red blood cells in buffer. The addition of acetylphenylhydrazine to washed red blood cells in buffer resulted in decreased folate levels after storage at 37°C for 24 h, but by 48 h, there was no longer an effect.

  • Biospecimens

    FluidBlood
    CellRed Blood Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    High hematocrit
    Low hematocrit
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Heparin
    Sodium fluoride
    Biospecimen Aliquots and ComponentsBlood and blood products
    Red blood cells
    Whole blood
    Biospecimen Aliquots and ComponentsHemolysis
    Absent
    Hemolysate added
    Present
    StorageShort-term storage solution
    5 mg/mL ascorbic acid
    Acetylphenylhydrazine
    Buffer with glucose
    Buffer without glucose
    Heat-inactivated plasma
    Iodoacetate
    No additive
    Plasma
    Plasma ultrafiltrate
    StorageStorage duration
    0 h
    24 h
    48 h
    72 h
    StorageStorage temperature
    37°C
    4°C