Skip to main content

Volume-reduced platelet concentrates: optimization of production and storage conditions.

Van der Meer PF, Bontekoe IJ, Kruit G, Peeters G, van Toledo PJ, Tomson B, de Korte D

Publication: Transfusion (2012) • Vol 52 • Page 819-27PMID: 21981439View on PubMed

Purpose

The purpose of this paper was to determine the effects of volume reduction on day 2 versus day 7 and storage container, solution and duration on markers of platelet (Plt) quality.

Conclusion

Room temperature storage of Plts led to significant decreases in pH, glucose levels and morphology scores, and increases in partial pressure carbon dioxide (pCO2), lactate and CD62P expression. Markers of Plt quality were generally better preserved when Plts were stored after volume reduction in butyryl trihexyl citrate (BTHC)-polyvinyl chloride (PVC) bags than when stored in syringes or diethylhexyl phthalate (DEHP)-PVC bags, when volume reduction was performed on day 2 rather than day 7, and when the Plts were resuspended in SSP+ rather than T-Sol or Composol.

Studies (2)

Purpose

The purpose of this study was to determine the effects of volume reduction on day 2 versus day 7 and storage container and duration on markers of Plt quality. 600 mL of buffy coat Plt concentrates in acid-citrate-dextrose-adenine (ACD-A) were volume reduced on day 2 or 7, resuspended in 15 mL, placed in the different storage containers and stored at room temperature.

Summary of Findings

In general, during Plt storage the pH and morphology scores decreased with storage (p<0.01, and p<0.05, respectively), and pCO2 increased (p<0.01), regardless of which day the volume reduction was performed. The changes were significant at a later time-point when specimens were stored in BTHC-PVC rather than in syringes, and pCO2 was not significantly different between Plts volume reduced on day 7 and stored in BTHC-PVC. Plts volume reduced on day 7 had higher CD62P expression after 6 h than after 0 h of storage for all containers (p<0.01, all). The pH was significantly higher in Plts volume reduced on day 2 and stored for 0-6 h in BTHC-PCV bags than in Plts stored in syringes (p<0.001) or DEHP-PVC (p<0.001) bags, and the pH was lower in Plts volume reduced on day 7 and stored for 0-6 h in BTHC-PVC bags than DEHP-PVC bags (p<0.05) and was also lower in Plts stored for 1-6 h in BTHC-PVC bags than syringes (p<0.01). pO2 was higher and pCO2 was lower in specimens stored in BTHC-PVC bags than in DEHP-PVC bags (p<0.01, both) or syringes (p<0.01, both). When volume reduced on day 2, the percentage of Plts expressing CD62P was significantly lower in Plts stored in syringes or DEHP-PVC bags than BTHC-PVC bags (p<0.05 and p<0.001), but when the Plts were volume reduced on day 7, the differences were not consistent between storage containers and timepoints. The percentage of Plts expressing annexin A5 was not consistently affected by storage container. Initially, the morphology score was not significantly different between Plts in the different storage containers, but after 6 h, scores were higher in Plts stored in BTHC-PVC than those in DEHP-PVC (p<0.01) or syringes (p<0.01). Further, glucose consumption and lactate production were higher in Plts stored in syringes or DEHP-PVC than Plts stored in BTHC-PVC (p<0.001 or p<0.05, respectively). Swirling effect was maintained when Plts were stored in BTHC-PVC containers, but was lost when stored in DEHP-PVC bags or syringes.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    GasClinical chemistry/auto analyzer
    MorphologyMacroscopic observation
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    0 h
    1 h
    3 h
    6 h
    StorageTime at room temperature
    2 days
    7 days
    StorageType of storage container
    BTHC-PVC bag
    DEHP-PVC bag
    Syringe