The purpose of this paper was to determine the effects of hemolysis on the levels of plasma glucose and insulin during glucose tolerance testing in children and adults.
Hemolysis is a major cause of variability in insulin measurement during oral glucose tolerance test in children.
Bellomo G, Sulas MG, Mairate E, Bardone MB, Rolla R
Purpose
Conclusion
Insulin levels and their variability during the glucose tolerance test were found to depend on the degree of specimen hemolysis, with a 50% reduction in measured insulin found when the concentration of free hemoglobin increased from 75 mg/dL to 125 mg/dL, but glucose levels and their variability during the course of the glucose tolerance test were unaffected by hemolysis. In a single plasma pool, insulin levels declined with increasing concentrations of added hemolysate (75-400 mg/dL hemoglobin) and the magnitude of the decrease increased with duration of storage of the specimen at room temperature. The frequency of hemolyzed specimens from children was greater than that for adults.
Studies (1)
Purpose
The purpose of this study was to determine the effects of hemolysis on the levels of plasma glucose and insulin during glucose tolerance testing in children and adults. Heparinized plasma was obtained from 35 13 year olds with growth hormone deficiency and 42 45 year olds with suspected impaired glucose tolerance. All specimens were obtained during glucose tolerance testing, and plasma was prepared and stored at room temperature until all specimens were analyzed together (within 240 min).
Summary of Findings
Insulin and glucose levels in children with growth hormone deficiency rose in the first 30 min following ingestion of dextrose and then declined steadily, but during the 2 hour course of the glucose tolerance test, the insulin levels had a very high variability. Insulin levels and their variability during the glucose tolerance test were found to depend on the degree of hemolysis, with a 50% reduction in measured insulin found when the concentration of free hemoglobin increased from 75 mg/dL to 125 mg/dL. In a single plasma pool, insulin levels declined with increasing concentrations of added hemolysate (75-400 mg/dL hemoglobin), and the magnitude of the decline increased with duration of plasma storage at room temperature. The authors note that the frequencies of hemolyzed specimens from children at 0 and 120 min were 30% and 42%, respectively, but from adults, the frequencies of hemolyzed specimens at 0 min and 120 min were 17% and 3%, respectively.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
Other diagnosesDiabetes Type 2Platforms
CarbohydrateClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerProteinSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Growth hormone deficiencyImpaired glucose tolerancePreaquisition Patient age 13 years old45 years oldBiospecimen Acquisition Time of biospecimen collection 120 min after dextrose ingestion30 min after dextrose ingestion60 min after dextrose ingestion90 min after dextrose ingestionBefore dextrose ingestionBiospecimen Aliquots and Components Hemolysis AbsentHemolysate addedNo hemolysate addedPresentStorage Time at room temperature 0 min120 min240 min60 min