A Predictive Factor of the Quality of Microarray Comparative Genomic Hybridization Analysis for Formalin-fixed Paraffin-embedded Archival Tissue.

Nakao K, Oikawa M, Arai J, Mussazhanova Z, Kondo H, Shichijo K, Nakashima M, Hayashi T, Yoshiura K, Hatachi T, Nagayasu T

Publication: Diagn Mol Pathol (2013) • Vol 22 • Page 174-80PMID: 23846445View on PubMed

Purpose

The purpose of this paper was to determine the effects of formalin fixation, storage duration and whole genome amplification (WGA) on DNA yield and DNA quality and the effects of WGA on array comparative genomic hybridization (aCGH) profiles in formalin-fixed paraffin embedded (FFPE) breast, lung and thyroid tumors.

Conclusion

Lower absorbance (A) at 260 to 230 , less double stranded DNA (dsDNA), and less labeling were observed with DNA extracted from FFPE specimens than the frozen counterparts, but the A260/A280 ratio was similar in frozen and FFPE specimens. For the two breast tumors with both frozen and FFPE specimens available, the aCGH profiles were similar between FFPE and frozen specimens. Of the 11 specimens showing HER-2 amplification by fluorescent in situ hybridization (FISH), 8 showed amplification by aCGH using FFPE specimens, and the sensitivity, specificity and accuracy of aCGH for Human Epidermal Growth Factor Receptor 2 (HER-2) status were 81.8%, 94.1%, and 89.3%, respectively. The derivative log ratio spread (DLRSpread) was modestly correlated with the storage time of the FFPE specimen and negatively correlated with dSDNA ratio and degree of labeling. Use of WGA did not improve aCGH results for FFPE specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of formalin fixation, storage duration and WGA on DNA yield and DNA quality and the effects of WGA on aCGH profiles in FFPE breast, lung and thyroid tumors. Regions with >70% tumor tissue were macrodissected from 10-20 10 uM sections and deparaffinized in xylene. Following digestion with proteinase K, DNA was extracted using QIAamp DNA mini kit.

Summary of Findings

Lower A at 260 to 230, less dsDNA and less labeling were observed with DNA extracted from FFPE specimens than the frozen counterparts, but the A260/A280 ratio was similar in frozen and FFPE specimens. For the two breast tumors with both frozen and FFPE specimens available, the aCGH profiles were similar between FFPE and frozen specimens. Of the 11 specimens showing HER-2 amplification by FISH, 8 showed amplification by aCGH using FFPE specimens, and the sensitivity, specificity and accuracy of aCGH for HER-2 status was 81.8%, 94.1%, and 89.3%, respectively. The DLRSpread was modestly correlated with the storage time of the FFPE specimen (r=0.551, p<0.0001) and negatively correlated with dSDNA ratio and degree of labeling (r=-0.796 and r=-0.481, respectively; p<0.001). Use of WGA did not improve aCGH results for FFPE specimens. The dsDNA yield, as determined by fluoremetry, was an indicator of aCGH performance.

  • Biospecimens

    TissueBreast
    TissueLung
    TissueThyroid Gland
  • Preservation Types

    FrozenFormalin
  • Diagnoses

    NeoplasticCarcinoma
    Neoplastic
  • Platforms

    DNAArray CGH
    DNAFluorometry
    DNAFISH
    DNASpectrophotometry
    DNAWhole genome amplification
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen
    StorageStorage duration
    1-43 years
    Whole genome amplification SpecificNucleic acid amplification
    Amplified
    Unamplified
    FISH SpecificTargeted nucleic acid
    HER-2
    Array CGH SpecificTechnology platform
    FISH